TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
86
3
2. Enter the appropriate information in the form as described below.
NOTE
: Available user interaction with this form will vary
depending on the Message Format selected in
Modify
Settings | Serial | Port #
n
.
Field Name
Action/Definition
Framing
Define the message framing
Header
Enter a character string for the header (ASCII or Hex). These characters will
be sent at beginning of every message. Up to 25 characters are allowed.
Trailer
Enter a character string for the trailer. These characters will be sent to
terminate every message.
Sequence
Select
No Sequence No., 1 Digit Sequence No., 2 Digit Sequence No.,
or
3 Digit Sequence No.
from the drop down list. When a digit sequence is
selected, a sequence number consisting of the specified number of digits is
inserted just after the header.
Check Digits
Select
BCC
or
CRC
from the drop-down list. When enabled, a two-character
hexadecimal check character is inserted just prior to the trailer.
Messages
Dim
Select
None
,
Send Dimensions
, or
User Defined
from the drop-down list.
None: No dimension data is sent in the message.
Send Dimensions: This selection sends the package dimensions in the
message.
User Defined: When selected, a text field is provided for entry of a user
defined message.
No Dim
Select
None
,
Send Dimensions
, or
User Defined
from the drop-down list.
None: No dimension data is sent in the message.
Send Dimensions: This selection sends the package dimensions in the
message.
User Defined: When selected, a text field is provided for entry of a user
defined message.
Содержание DM3610
Страница 1: ......
Страница 25: ...MECHANICAL INSTALLATION 15 2 Figure 15 DM3610 Mounting Dimensions with UMB ...
Страница 53: ...ELECTRICAL INSTALLATION 43 3 3 9 2 Photoelectric Sensor PNP Figure 39 Photoelectric Sensor Wiring PNP Output ...
Страница 151: ...141 ...
Страница 156: ......
Страница 157: ......