TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
38
3
3.2 INSTALLATION SEQUENCE
NOTE:
Everything should be
MECHANICALLY INSTALLED
before
performing any
ELECTRICAL INSTALLATION
.
See chapter 2 for mechanical
installation details.
Most DM3610 applications are shipped with the CBX100 connection box and
all the necessary cabling required to electrically install the system. If your
system requires custom-length cables or other special wiring, documentation
specific to these requirements has been provided in your shipment. This
special documentation supersedes any contradictory content in this manual.
NOTE:
To reduce the possibility of damage to the unit, check all cabling
between the DM3610 and other devices for accuracy.
3.2.1 Connecting a DM3610-3100/3200/3300 Singulated, non-touching
To install a two-head dimensioning system, follow this sequence:
Complete mechanical installation
(See chapter 2.)
Complete electrical installation.
(See wiring illustrations provided in this chapter.)
Observe all electrical safety requirements outlined in this chapter.
Ground the mounting structure to protective earth (PE) ground.
If used, wire the photoelectric sensor (or other trigger) to the CBX connection box.
Wire the tachometer to the CBX connection box (if used).
Wire serial ports to the CBX connection box if needed.
Connect the dimensioner cabling to the CBX connection box and DC3000 Controller
as required by your application.
Wire the monitor to the CBX connection box.
Connect the power supplies to the equipment.
Connect the power supply to the power source.
Setup / check dimensioning system operations
(See chapter 5.)