3.5 POWER CONNECTIONS
IMPORTANT:
When planning your installation wiring, remember all power
connections must be quick-disconnect.
CAUTION:
While performing the following wiring connection procedures, be sure to
follow all safety procedures regarding high-voltage as outlined in the Introduction to
this manual. No power should be applied to any device until all wiring is completed
and checked for accuracy.
IMPORTANT:
The socket-outlet must be installed near the DM3610. The outlet
must be a readily accessible disconnect device.
Ground the DM3610 to safety ground (protective earth ground (PE)). See wiring
recommendations for safety ground.
The CBX510 connection box provides flexible connectivity to a range of I/O devices as well
as serial hosting. The Master DM3610 connects to the CBX510 via its I/O port using a single
17-pin M12 to 25-pin D cable.
The following block diagrams show interconnections for 2-head dimensioning system.
Figure 36: Wiring Block Diagram
The system requires a CBX510 Connection Box and DC3000 Controller. The CBX510
provides easy wiring to tachometer and triggers, while the DC3000 Controller provides
connections to the Host network. The DC3000 Controller also includes the User Interface
and backup/Alibi storage.