TWO-HEAD DIMENSIONING SYSTEM REFERENCE MANUAL
66
3
Field Name
Action/Definition
Belt Analysis
Head Pitch
Estimate 1 and 2
Enter
Head Pitch Estimate 1
(HEAD1) and
Head Pitch Estimate 2
(HEAD2) based on the angles from the application specifications.
This will be a positive degree integer for each head (no negative
degree indication). The
Head Pitch Estimate
helps each head
differentiate the conveyor bed from the beam catcher.
Find Belt
Click
Find Belt
to automatically determine the
Scanner Heights,
Left Ignore, Right Ignore, X Shift, Y Shift,
and
X Rotation
.
NOTE:
When
Find Belt
is clicked, the system calculates
each dimensioner’s position over the conveyor.
If the data from each dimensioning head does not agree, the
following warning may appear:
WARNING:
heads disagree on belt width by more than 5cm
[2”]
The calculated data is automatically entered in the Find Belt fields
under Dimensioning Area