Product Manual - DM991 Series V Family - 204.4092.08
52
o
Drop insert: insert: this configuration makes the received unused timeslots to be
retransmitted, enabling the drop insert of several equipments in the same E1
link;
o
Idle: this configuration retransmits the user configured value in the “Idle byte”
parameter, in each unused timeslot.
10.5.5. Bridge Interface Configuration Menu (only for DM991CE and DM991SE)
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991CE - G.SHDSL Modem With Ethernet Bridge
#
--------------------------------------------------------------------------
#
Bridge Configuration
#
#
Enable operation :[ Yes ]
#
WAN Data Rate :[ 03 ]
#
Duplex :[ Full-Duplex ]
#
Link Speed :[ 100 Mbit/s ]
#
Enable Auto Negotiation :[ Yes ]
#
Enable Back Pressure :[ Yes ]
#
Enable Pause Frames :[ Yes ]
#
#
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Save and Exit <TAB> Change <N>ext
#
--------------------------------------------------------------------------
•
Enable operation: enables or disables the interface.
•
Wan data rate - number of timeslots used on the interface (Nx64kbit/s, up to the
aggregate limit).
•
Duplex: chooses between the operational modes:
o
Half- Duplex: uses a single band direction at a time;
o
Full- Duplex: uses both band directions simultaneously.
•
Link speed: chooses Ethernet port speed, in the LAN direction, between 100Mbit/s or
10Mbit/s.
•
Enable auto negotiation: enables or disables the interface parameters auto negotiation.
•
Enable back pressure: allows enabling the interface flow control, when using half duplex
mode.
•
Enable pause frames: allows enabling the interface flow control, when in full-duplex mode.
10.6. Test Menu
On the tests menu the access to the test commands is individual for each interface.
In all test menus, whatever the interface, there is an indication of the status of the tests on the interface.