7 - Visualize activation LOG: This option presents a LOG containing the errors when
partially invalid or invalid configurations try to be activated.
10.5.1. Equipment General Configurations Menu
On this menu, pressing TAB will change the value of the object to be configured.
Press ENTER to exit this menu and save the changes in the user memory, and ESC to exit and cancel the
changes.
This menu can be accessed by pressing “G” on the configuration menu and is destined to the equipment
global clock configuration and to the enabling or not of destructive configurations to the management link.
•
Clock Source: configures the transmission clock of the equipment. The options are:
internal and regenerated (of the DSL, E1 or digital interface).
•
Enable destructive configuration: enables or disables the destructive configurations for the
remote management. It is necessary to enable this object in case the user wants to
disable the remote management through the EOC on the G.shdsl interface or to disable
the G.shdsl interface (enable converter mode).
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
General Configuration
#
#
Clock source :[ Regenerated from G.SHDSL ]
#
Enable destructive configuration :[ No ]
#
#
#
#
#
#
#
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Save and Exit <TAB> Change <N>ext
#
--------------------------------------------------------------------------
The clock can be regenerated from any one of the interfaces or be internally generated by the equipment.
However, all the interfaces, aggregate and tributaries should be in synch or referenced to the same synch