10.5.2. G.shdsl Interface Configuration Menu
#
--------------------------------------------------------------------------
#
D A T A C O M [ 1 ]
#
DM991C - G.SHDSL Modem - E1 and V.35 Interfaces
#
--------------------------------------------------------------------------
#
G.SHDSL Configuration
#
#
Enable Operation :[ Yes ]
#
Enable tests :[ Yes ]
#
Enable RDL reception :[ Yes ]
#
Number of channels :[ 32 ]
#
Remote management :[ Use EOC bits ]
#
Unit type :[ NTU ]
#
Annex :[ Automatic ]
#
Frame mode :[ Automatic ]
#
Line Operation :[ 2 Wires ]
#
#
#
#
#
#
#
--------------------------------------------------------------------------
#
<P>revious <ESC> Exit <ENTER> Save and Exit <TAB> Change <N>ext
#
--------------------------------------------------------------------------
•
Enable Operation: enables or disables the interface, when disabled the modem to take on
Converter Mode.
•
Enable tests: enables the test activation on this interface through the test menu or through
the management.
•
Enable RDL reception: informs if the interface should recognize and accept the LDR
request, through the remote modem and go into loop.
•
Number of channels: It can range from 1 to 36 2-wire channels and 1 to 72 4-wire
channels.
•
Remote management: Allows to configure the G.shdsl interface management channel or
to disable it.
•
Operation mode: determines if the modem operates as LTU (central) or as NTU (user).
•
Annex : Can be configured as annex A, B or automatic selection.
•
Frame mode: selects synchronous, plesiochronous or automatic mode.
•
Line Operation: Enables operation in the line, on 2 wires or 4 wires.
This option is available only for models DM991S and DM991C. In order to disable the G.shdsl interface,
you have to enable the destructive settings in the general equipment settings menu.