Hardware Installation
(LM2000 NIC)
Please note that daisy-chaining capability is limited to four
WAN
switches
™
, thereby providing access to as many as 32
segments using four 8 port WAN
switches
™
. The explanation
below will focus on the Pentium II Sniffer Technologies sin-
gle port WAN RS/V (LM 2000 NIC) Analyzer running
Sniffer
®
Distributed Analysis Software installation configu-
ration to multiple W2358D
SL
WAN
switches
™
shown in
Figure C2
. The installer will eliminate some connections
discussed if only one DSS Analyzer is present. To make
interconnection between multiple WAN
switches
™
, two
Analyzers, and individual network links, follow the steps
below:
Step 1:
(
NOTE
:
If a
WAN
switch
™
is to be used in a mixed
switch daisy-chain, it must be the first switch.
) Install each
switch in the order that corresponds to it’s respective switch
address. Connect the
MONITOR
port of each DSS to the
Common A
and
Common B
ports, respectively, of the first
WAN
switch
™
using DRL312-3 cables. Then connect the
Daisy
A
and
Daisy B
ports of the first WAN
switch
™
to the
Common A
and
Common B
ports, respectively, of the second WAN
switch
™
using DRL312-3 cables. Any subsequent daisy-chained
WAN
switches
™
have their
Daisy A
and
Daisy B
ports connect-
ed to the
Common A
and
Common B
ports, respectively, of the
next WAN
switch
™
using a DRL312-3 cable.
Step 2:
Connect the DRL341-3-3 Control Y-cable DB9
Male lead labeled “
A
” to the
COM 1
port of one of the DSS
Analyzers.
NOTE:
For single DSS Analyzer or daisy-chain installations
the DB9 Male lead labeled “
B
” has been factory tie-
wrapped into a 2-inch coil approximately 8-inches from the
common connector so it can be easily stored above, below, or
hang innocuously behind the DSI switch. To install two
Analyzers the DB9 Male lead labeled “
B
” tie-wrap is
removed to make the entire lead length available for instal-
lation.
Step 3:
Connect the DRL341-3-3 Control Y-cable DB9
Male lead labeled “
B
” to the
COM 1
port of the other DSS
Analyzer.
Step 4:
Connect the DB9 Female lead of the DRL341-3-3
Control Y-cable to the
Control
port of the WAN
switch
™
. Any
subsequent daisy-chained WAN
switches
™
connect their
their
Link
port using a DRL341-3-3 Control Y-cable DB9
Male lead labeled “
A
” connected to the
Control
port of the
next WAN
switch
™
with the DB9 Female lead of the DRL341-
3-3 Control Y-cable.
Step 5:
Connect network cables to the desired
Network
ports
of each WAN
switch
™
.
Step6:
Connect the Power Supply 5-pin DIN Male connector
into the
Power
port of the WAN
switch
™
and then plug the
Power Supply into the external power source wall receptacle.
A green light within the center of the Datacom front panel
logo indicates power is on.
After the daisy-chain hardware installation is complete, the
switch control software must be configured or reconfigured.
Refer to the DATACOM
switch
SOFTWARE
guide
.
C3
D
DA
AI
IS
SY
Y-
-C
CH
HA
AI
IN
N
Содержание WANswitch W2358DSL
Страница 2: ......
Страница 3: ...i March 2002 W2358DSL Part Number 541 0052 C 01 WANswitch HARDWAREguide ...
Страница 4: ...ii ...
Страница 19: ...B4 Figure B2 W2358DSL Rear Panel 2 1 4 3 6 5 8 7 Common A Daisy A Link Control Power Links Common B Daisy B ...
Страница 27: ...D2 ...
Страница 29: ...D4 ...
Страница 31: ...D6 ...
Страница 33: ...E2 ...
Страница 35: ......