Daisy-Chain Addressing
IMPORTANT
PRIOR
to installing any WAN
switch
™
in a
daisy-chain
, the
address of each individual switch must be set one switch at a
time to perform the daisy-chain address configuration. The
hardware connection to perform this configuration from a
stand-alone computer platform is explained next. After the
hardware connection has been accomplished, the address of
each individual switch must be set one at a time with the
ATTACH
it
program as described in the DATACOM
switch
SOFTWARE
guide
.
Connection Instructions
The typical daisy-chain addressing installation described
herein will be for a WAN
switch
™
.
Step 1:
Connect the
COM1
port of the computer platform to
the
Control
port of the WAN
switch
™
using a DRL341-3-3
cable as shown
Figure C1
.
Step 2:
Connect the Power Supply 5-pin DIN Male connector
into the
Power
port of the WAN
switch
™
and then plug the
Power Supply into the external power source wall receptacle.
A green light within the center of the Datacom front panel logo
indicates power is on.