2.2 Requirements Before Construction
2.2.1 EOC Master Requirements Before Construction
2.2.1.1 EOC Master Installation Requirements
1. The device should not be installed near large power transmission and transformation
equipment, radio signal transmission towers and other facilities.
2. The equipment should not be placed in a humid environment such as a basement.
3. It is strictly prohibited to stack flammable, explosive, strong corrosive and other
dangerous goods around the equipment.
4. The design of the internal equipment installation location should consider the
long-term development needs of the project, and appropriately leave room for
hardware expansion and installation.
5. The interior of the equipment room should be reasonably installed and arranged so
that the equipment and installation accessories are arranged as neatly as possible to
facilitate maintenance.
6. The installation of the EOC master should adopt reliable seismic reinforcement
measures to prevent hardware damage caused by accidental drop.
7. The equipment installation environment should provide a stable grounding condition,
and its design should meet the specification requirements.
8. AC power line should be made of flame-retardant materials and sheathed.
2.2.1.2 EOC Master Operating Environment Requirements
1. Temperature and humidity requirements:
Temperature: -10
~
55
℃
Humidity: 20
~
85%(Non-condensing)
2.
Cleanliness requirements:
Dust particles must not be conductive, ferromagnetic, or corrosive. The concentration of
dust particles with a diameter greater than
0.5μm
is less than 3500 particles/L. The
concentration of dust particles with a diameter greater than
5μm
is less than 30 particles/L.