Digital I/O Specifications
lists the specifications for the digital input and digital output subsystems on a
DT9816 Series module.
Table 26: Digital I/O Subsystem Specifications
Feature
Specifications
Number of digital I/O lines
16 (8 each; dedicated)
Number of ports
2, 8-bit
Input termination
Series 1 k
Ω
; Series 33.2
Ω
Logic family
TTL
Logic sense
Positive true
Inputs
Input type:
Input logic load:
High input voltage:
Low input voltage:
Low input current:
Level sensitive
1 TTL Load
2.4 V min
0.8 V max
–0.4 mA max
Outputs
High output:
Low output:
High output current (source):
Low output current (sink):
2.8 V min
0.6 V max
4.5 mA
10 mA
Software I/O selectable
Yes
ESD protection (per spec)
Arc:
Contact:
8 kV
4 kV
Содержание DT9816 Series
Страница 1: ...DT9816 Series UM 21336 X User s Manual Title Page ...
Страница 4: ......
Страница 8: ...Contents 8 ...
Страница 12: ...About this Manual 12 ...
Страница 13: ...13 1 Overview Key Hardware Features 14 Supported Software 16 Getting Started Procedure 19 ...
Страница 20: ...Chapter 1 20 ...
Страница 21: ...Part 1 Getting Started ...
Страница 22: ......
Страница 44: ...Chapter 3 44 ...
Страница 54: ...Chapter 4 54 ...
Страница 55: ...Part 2 Using Your Module ...
Страница 56: ......
Страница 57: ...57 5 Principles of Operation Analog Input Features 59 Digital I O Features 64 Counter Timer Features 65 ...
Страница 81: ...81 7 Troubleshooting General Checklist 82 Technical Support 84 If Your Module Needs Factory Service 85 ...
Страница 86: ...Chapter 7 86 ...
Страница 102: ...Appendix B 102 ...
Страница 108: ...Index 108 ...