background image

 

LED signalling of the electronic card inputs (verifiable after switching on the power supply to the unit) 
DL1

  Always illuminated, un-illuminated with intervention of 

COSTA

 

DL5 

Always illuminated, un-illuminated with intervention of 

STOP

 

DL2

  Always illuminated, un-illuminated with intervention of 

FCC

 

DL6 

Always un-illuminated, illuminated with the operation 

SEQ/START

 

DL3

  Always illuminated, un-illuminated with intervention of 

FCA

 

DL7 

Always un-illuminated, illuminated with the operation 

CH/P

 

DL4 

Always illuminated, un-illuminated with intervention of 

FOTO

 

DL8 

Always un-illuminated, illuminated with the operation 

APRE

 

In the event that signalling does not correspond to the above, check the connections and the efficiency of the various connected 
devices.  

5.  Radio code entry 

It is possible to store 128 rolling code radio controlled operations plus 128 fixed code radio controlled operations. 

Radio controlled storage for input SEQ (it is advisable to proceed step by step) 

 Hold 

down 

the 

P2 

button until the 

DL10 

LED starts flashing.  

 Release 

the 

P2 

button and activate the radio controlled operation to be memorised. When the 

DL10 

LED remains illuminated for 

about 1 second and then switches off, the radio controlled operation is set. If on the other hand LEDs 

DL9

DL10 and DL11 

flash 

for about 3 seconds then switch off, the operation has not been stored successfully due to having reached the maximum number 
of radio controlled operations. 

N.B. 

Immediately after the storage of a radio controlled operation, the receiver will remain de-activated for about 3 seconds, in order to 

avoid unwanted operation of the gate after the setting operation itself. It is however possible to store a new radio controlled operation 
immediately by repeating the procedures described above. 

Deleting a radio controlled operation 

 Hold 

down 

the 

P2 

button until the 

DL10 

LED starts flashing; do not release the button, wait for the flashing to increase in 

frequency; continue holding down the button and wait for a further increase in frequency.  

 Release 

the 

P2 

button and activate the radio controlled operation to be cancelled. When the LED 

DL10 

switches off, the radio 

controlled operation has been cancelled. 

Complete deletion of all radio controlled operations 

 

Switch off the apparatus and switch it on again, holding down the 

P2 

button.

 

After a few seconds the 

DL10 

LED will start flashing 

at very high frequency; continue to hold the button down for about 5 seconds until the 

DL10 

LED switches off. At this point all the 

radio controlled operations have been deleted from memory. 

Radio controlled storage for output SPIA (21-22) 

 Hold 

down 

the 

P1 

button until the 

DL11 

LED starts flashing.  

 Release 

the 

P1 

button and activate the radio controlled operation to be stored. When the 

DL11 

LED remains illuminated for about 

1 second then switches off, the radio controlled operation has been set. When the transmitter is pressed, the 

SPIA

 contact is 

activated for 1 second, losing the operation of the gate light. If on the other hand LEDs 

DL9

DL10 and DL11 

flash for about 3 

seconds then switch off, the operation has not been stored successfully due to having reached the maximum number of radio 
controlled operations. 

Deleting a radio controlled operation for output SPIA (21-22) 

 Hold 

down 

the 

P1 

button until the 

DL11 

LED starts flashing; do not release the button, wait for the flashing to increase in 

frequency; continue holding down the button and wait for a further increase in frequency.  

 Release 

the 

P2 

button and activate the radio controlled operation to be cancelled. When the LED 

DL11 

is no longer illuminated, 

the radio controlled operation has been cancelled. If all transmitters are cancelled ouptuts 21 and 22 resume gate light operation. 

N.B. If inputs which are normally closed (N.C.) are not being used, they should be bridged.  

If several N.C. contacts are used on the same terminal they should be connected in series. If several N.A. contacts are used on the 
same terminal they should be connected in parallel. 


Motor output 24V DC. 

14 
16 

Input for closing limit switch 
N.C. contact 


 

Out put for the boom light. Flashing while the boom is 
moving and flashing slowly while barrier is closed 

15 
16 

Input SAFETY EDGE (COSTA).  


 

Flashing light output: intermittent output 24Vd DC max 
10W 

17 
18 

Output 24 V DC photocell-accessory power 
supply. 17 + / 18 - (max 500mA) 


11 

 

Input OPEN, with gate stationary activates opening, with 
gate in motion activates a reverse operation 

19 
20 

Output LOCK in opening is activated for 1 sec  
(12V DC mA  15VA) 


11 

 

In put CH/P, it controls the closing 
 

21 
22 

 

Output SPIA: clean contact, it closes when barrier 
is opened (traffic light feature) possibility of 
inverting contact state from N.C. to N.O. through 
jumper JP1(maximum applicable voltage 3A 24V 
DC or 2A  125V aAC) 

 9 
11 

 

Input SEQ activates opening when the gate is closed, the 
stop operation during opening (if DIP2 = OFF), closing 
when the gate is open, and re-opening during closure

 

23 
24 

Antenna input to connect the ‘hot’ pole of the 
antenna to terminal 23 and the braid to terminal 
24 

 

10 
11 

 

Input STOP  

CN4

Connector for secondary input of the transformer 
voltage 22-0-22 V AC 

12 
16 

Input PHOTO 

CN2

Connector for programming connection 

13 
16 

Input for opening limit switch 
N.C. contact 

 

 

6.  Programming and testing should be carried out after installing all signalling and safety devices stipulated by current 

legislation, in order to reduce risk of injury as much as possible. 

Preliminary checks: 

 

Switch the unit on. 

 

Check that all N.C. contacts (contacts normally closed) for each LED are switched on. If not, check the contacts on the devices 

Содержание GIGA4ECORX433

Страница 1: ...Vi Italy tel 39 0445 602261 fax 39 0445 585035 www daspi it info daspi it GIGA4ECORX433 Centrale di comando per barriere a 24 Volt Control unit for 24 Volt barriers Centrale de commande pour barri re...

Страница 2: ...ulsante P2 e attivare il radiocomando che si vuole memorizzare Quando il led DL10 rimane acceso per circa 1 secondo e poi si spegne il radiocomando appreso Se invece i led DL9 DL10 e DL11 lampeggiano...

Страница 3: ...ui trimmer TR1 TR4 eseguire la regolazione della velocit desiderata durante il rallentamento in apertura e in chiusura Agendo sui trimmer TR2 TR3 eseguire la corretta regolazione della coppia accertan...

Страница 4: ...nd activate the radio controlled operation to be stored When the DL11 LED remains illuminated for about 1 second then switches off the radio controlled operation has been set When the transmitter is p...

Страница 5: ...losive Conserver scrupuleusement le pr sent manuel en l annexant au fascicule technique de l installation dans un endroit ad quat et connu de tous les int ress s afin qu il soit disponible dans le fut...

Страница 6: ...0 mA 7 11 Entr e OUVRE avec portail arr t commande une ouverture avec portail en mouvement commande une inversion 19 20 Sortie SERRURE l ouverture est activ e pendant 1 sec 12 Vcc mA 15 VA 8 11 Entr e...

Страница 7: ...ontrolar despu s de haber alimentado la central DL1 Siempre encendido se apaga cuando intervenga el BORDE COSTA DL5 Siempre encendido se apaga en el momento de la STOP DL2 Siempre encendido se apaga e...

Страница 8: ...entar el ctricamente la central Comprobar que todos los leds de se alizaci n de los contactos normalmente cerrados N C se encuentren encendidos de lo contrario controlar los contactos de los dispositi...

Отзывы: