9
Press [
] [6] [3] [#] [MASTER CODE] [#]
(To enter the programming sequence for phone number three)
Now enter the required number, not exceeding 16 digits for pulse dialing or 15 digits for tone
dialing.
Enter Phone Number. Example: [9] [7] [0] [7] [4] [3] [1] [1] [
] (the
is a 4 second pause).
Finally enter [#] to mark the end of your programming sequence.
The full sequence for entering the phone number 97074311 into phone number one, with a
four second pause is as follows:
[
] [6] [1] [MASTER CODE] [#] [9] [7] [0] [7] [4] [3] [1] [1] [
] [#]
REVIEWING PHONE NUMBERS IN THE RUN MODE
Once the [#] is pressed to mark the end of the phone number, the DL100 will then read back the
entered number, (ignoring 15's and 13's) displaying it on the LED code pad.
The numbers will be represented by the LED’s on the LED code pad. Zone LEDs 1 to 6 will
represent digits 1 to 6. The Armed LED will represent digit 7, the ready LED will represent digit
8, the Partial LED will represent digit 9, and the Power LED will represent digit 0. Refer to the
table below for details:
CODE PAD
LEDS
PHONE DIGIT
CODE PAD
LEDS
PHONE DIGITS
Armed
7
Zone 1
1
Ready
8
Zone 2
2
Partial
9
Zone 3
3
Power
0
Zone 4
4
Zone 5
5
Zone 6
6
Each LED will turn on for 1 second and will have a 500mS delay between LEDs. To mark the
end of the display, all the LEDs will turn on for 200mS and the code pad will beep once.
To review a phone number without entering a new one into programming, press [
] [6] [1] [#],
[
] [6] [2] [#], or [
] [6] [3] [#] followed by the master code and then pressing the [#] key. If you
have not entered a number, the existing number will be displayed.
DELETING PHONE NUMBERS
To delete a phone number, press [
] [7] [1] [#] for phone number 1, [
] [7] [2] [#] for phone
number 2, or [
] [7] [3] [#] for phone number 3, followed by the master code and then pressing
the [#] key. To mark a phone number deletion, all the LEDs will turn on for 200mS and the code
pad will beep once.
RESETTING YOUR SECURITY CONTROL CENTER
In the event of a system malfunction in the Security Control Center, press the [#] (reset) key on
the code pad control. This should reset the code sequence and restore normal operation. If the
problem persists, call the service number located on page 1 of this booklet for service.