I NS TA LL A TI ON M A NU A L
H 5 0 0 1 H Y BR I D I NV E R T ER
R E V . 4
©20 2 2 D A R F ON E LEC TR ON I CS COR P.
20
| P A G E
Testing the Emergency Button
Turn on the system and wait for it to bootup.
Press the emergency shutdown button. The inverter will immediately shut down.
Note: If the inverter did not shutdown. Check the wiring and make sure the connectors are seated properly. Check for
conductor continuity as well.
Reset the emergency button.
Resetting the Emergency Button
Remove the safety cover. While pressing the button down,
pull the safety cover away.
Reset the emergency button. Rotate button clockwise. The
button will pop back to the starting position.
Reset the safety cover. Push the top section of the safety
cover onto the base until it clicks into place.
Put the safety cover back over the button. Be careful not
accidentally press the button.
Troubleshooting
If the inverter shuts down immediately after it is turned on, the emergency button may have been set incorrectly. Open the
emergency button and check the wiring.
Unscrew the four screws and pull the base apart.
Confirm the wires are connected to a terminal labelled
“NO”. Rewire to a “NO” terminal if the wiring is incorrect.