EMB-OPT01 User’s Manual
13
[Table 4. CN1/CN2 SFP Connector]
No.
Name
Description
Remark
1
VeeT
Transmitter Ground
2
TxFault
Transmitter Fault
3
TxDisable
Transmitter Disable
4
SDA
Serial Interface Data Line
5
SCL
Serial Interface Clock
6
MOD-ABS
Module Absent, connected to VeeT or VeeR
7
RS0
Rx Rate Select
Open or Low = 2.125 or 4.25 Gb/s Fibre Channel (Low
Bandwidth)
High = 8.5 Gb/s Fibre Channel (High Bandwidth)
8
LOS
When high, indicates received optical power below
worst-case receiver sensitivity.
9
RS1
Tx Rate Select
Open or Low = 2.125 or 4.25 Gb/s Fibre Channel (Low
Bandwidth)
High = 8.5 Gb/s Fibre Channel (High Bandwidth)
10
VeeR
Receiver Ground
11
VeeR
Receiver Ground
12
RD-
Receiver Data
13
RD+
Receiver Inverted Data
14
VeeR
Receiver Ground
15
VccR
Receiver Power(3.3V)
16
VccT
Transmitter Power(3.3V)
17
VeeT
Transmitter Ground
18
TD+
Transmitter Data
19
TD-
Transmitter Inverted Data
20
VeeT
Transmitter Ground
(Note) For detailed specifications, refer to the Camera Link standard document.