5
www.danvex.fi
1.2
Application area
DEH-i series dehumidifiers use the condensing method of dehumidification and are able
to effectively dehumidify the air and automatically maintain the desired humidity level
at atmospheric pressure in the range of 40-100% relative humidity and operating range
temperatures from
+5°C
to
+32°C.
This series of condensing dryers are widely used in the following fields
:
•
elimination of consequences flooding of various heated premises with water
;
•
heated warehouses for packaging and finished products
;
•
production of internal wet construction and finishing works
;
•
production and storage of confectionery products and foodstuffs
;
•
storage and aging of cheeses
;
•
drying fish, vegetables and fruits, starch
;
•
painting cameras
;
•
test laboratories
;
•
production facilities with high-precision equipment
;
•
rooms with open reservoirs and pools
;
•
premises that require frequent wet cleaning and laundry
;
•
pumping stations
;
•
production zonesinjection molding
;
•
and etc
.
2
INFORMATIONABOUT YOUR DEVICE
2.1
Standards
The design of the dehumidifiers corresponds to the protection class IP22, IEC standard
.
2.2
Description and principle of operation
The unit is designed for automatic and uninterrupted dehumidification and maintenance
air humidity at atmospheric pressure.
The operation of the dehumidifier is based on the principle of condensation of moisture from
the air. During operation of the dryer, moist air is sucked into the dryer by a fan and, passing
through two heat exchangers of the compressor refrigeration machine, is first cooled in the "cold"
heat exchanger (evaporator) to the dew point temperature with condensation, and then heated
in the "warm" heat exchanger (condenser) and is discharged from the dehumidifier into the room
to be dried. The moisture released from the air in the form of condensate flows into the inner tray,
and then by gravity, at the user's choice, is discharged either into the built-in removable tank
or directly into the sewer system.
Dehumidifier management and control carried out through the control panel equipped with
an LCD display. The display can show current and adjustable parameters, operating modes,
as well as service information in case of a malfunction.