background image

9

www.danvex.fi

The timer is set using the 

TIMER, + / -

 buttons and is possible both to turn off the dehumidifier 

from the working state, and to turn on the dehumidifier from the non-working state. 
Settings are made in the corresponding modes

TO DISABLE 

in operating mode, press TIMER once, then +/- to set time in hours 

(range 1–24 hours)

;

ON 

in idle mode, press TIMER once, then +/- to set time in hours (range 1–24 hours

).

Attention

:

The dehumidifier will not start if the humidity level set in the settings is higher than 
current humidity

;

The dehumidifier will not start if the tank is full or missing

;

When operating in cold conditions, the compressor of the dryer may turn off to perform 
a defrost, and the defrost indicator will light up on the display

  

         

;

The display shows humidity in the range from 

30% 

to

 90%;

If the dehumidifier is not to be used for a long time, unplug it

.

   MAINTENANCE

Before starting any maintenance work maintenance, 

be sure to disconnect the dehumidifier from the mains

5.1 

  Introduction

It is important to regularly inspect, maintain and clean the main components of the dryer to ensure 
a long service life and trouble-free operation. The frequency of maintenance depends on the 
operating conditions of the dryer. Thus, the maintenance cycle can be determined based on actual 
operation. Incomplete and incorrect maintenance can reduce efficiency dryer or damage it.

5.2 

  Frame

Dust and other substances must not accumulate on the body of the dryer. It is recommended 
to clean the case with a dry or slightly damp cloth without the use of solvents or abrasive detergents. 
Use only non-aggressive cleaning agents, even if the unit is heavily soiled. 

It is forbidden to clean the unit under the jet water!

5.3 

  Filter

The dehumidifier is equipped washable coarse air filter at the inlet. It protects the dryer heat 
exchangers from fluff and household dust. Do not run the dryer without a filter. 
It is recommended to clean the filter as it becomes clogged, but at least once every 2

 

weeks

.

5.4 

  Heat exchanger

 

With the right operating the dryer with the air filter installed, the heat exchanger does not require 

any maintenance. 

Содержание DEH-500i

Страница 1: ...Manual Air dehumifiers DEH 500i DEH 900i DEH 1200i rev 3 12...

Страница 2: ...DEVICE INFO 5 2 1 Standards 5 2 2 Description and principle of operation 5 2 3 Design 6 3 MOVEMENT AND INSTALLATION SITE 7 4 STARTING AND OPERATION 7 4 1 Electrical connection 7 4 2 Control Panel 8 4...

Страница 3: ...2 www danvex fi 6 DIAGNOSTICS AND TROUBLESHOOTING 10 7 DRYER CHARACTERISTICS 11 8 PERFORMANCE GRAPHS 12 9 DIMENSIONS 12 9 WIRING DIAGRAM 13...

Страница 4: ...contains general information on safety and applications principle of operation dehumidification process control maintenance procedures diagnosis and troubleshooting Copyright We reserve all rights to...

Страница 5: ...e only and does not remove the user s responsibility for compliance with personal safety requirements and local safety standards In equipment operation each user is obliged to follow the instructions...

Страница 6: ...CE 2 1 Standards The design of the dehumidifiers corresponds to the protection class IP22 IEC standard 2 2 Description and principle of operation The unit is designed for automatic and uninterrupted d...

Страница 7: ...upplied corrugated hose from the fitting to the sewer from the outside In this case the dehumidifier can operate continuously without stopping to drain the condensate from a filled tank When freezing...

Страница 8: ...rged into the built in tank or from the dehumidifier if possible place the dehumidifier in the center of the room to be dried or in the middle of a long wall to ensure optimal air circulation do not c...

Страница 9: ...humidity parameter or the timer parameter decreasing the humidity setting or the timer setting 4 3 How to operate and set parameters The dehumidifier is switched on by pressing the ON OFF button once...

Страница 10: ...from the mains 5 1 Introduction It is important to regularly inspect maintain and clean the main components of the dryer to ensure a long service life and trouble free operation The frequency of maint...

Страница 11: ...ng lasting during operation the installation was subjected to control and testing during the manufacturing process However in case of problems during operation please use the following recommendations...

Страница 12: ...f the compressor and its failure which is not covered by the warranty 7 DRYER CHARACTERISTICS Model DEH 500i DEH 900i DEH 1200i Productivity at 30 80 RH l day 50 90 120 Operating temperature range 5 3...

Страница 13: ...city L 24 Hours Air temperature DEH 500i 40 50 60 70 80 0 20 40 60 80 100 120 140 10 15 20 25 30 Dehumidification capacity L 24 Hours Air temperature DEH 1200i 40 50 60 70 80 0 10 20 30 40 50 60 70 80...

Страница 14: ...13 www danvex fi 10 ELECTRIC SCHEME DEH 900i 1200i...