Parameter
Function
Record Delay
System can delay the record for specified time after alarm
ended. The value ranges from 10s to 300s.
Alarm out
Enable alarm activation function. User need to select
alarm output port so that system can activate
corresponding alarm device when an alarm occurs.
Latch
System can delay the alarm output for specified time after
an alarm ended. The value ranges from 1s to 300s.
Show message
System can pop up a message to alarm user in the local
host screen if user enabled this function.
Buzzer
Check the box here to enable this function. The buzzer
beeps when an alarm occurs.
Alarm upload
System can upload the alarm signal to the centre
(Including alarm centre).
Send Email
If user enabled this function, System can send out an
email to alert user when an alarm occurs.
Tour
User need to click setup button to select tour channel.
System begins 1-wiindow or multiple-window tour display
among the channel(s) user set to record when an alarm
occurs. See Figure 7-64.
PTZ Activation
Here user can set PTZ movement when alarm occurs.
Such as go to preset X. See Figure 7-70.
Snapshot
Click setup button to select snapshot channel. See Figure
7-65.
7.9.3.2.2 Net Alarm
The network alarm interface is shown as in Figure 7-71.
Network alarm refers to the alarm signal from the network. System does not anti-dither and
sensor type setup. For setup information, please refer to chapter 7.9.3.2.1.
Содержание DNA2000 Series
Страница 67: ...Figure 5 58 Figure 5 59 Figure 5 60...
Страница 105: ...Figure 5 120...
Страница 134: ...Figure 7 35 Figure 7 36 Figure 7 37...
Страница 148: ...Figure 7 60 Figure 7 61...
Страница 149: ...Figure 7 62 Figure 7 63...
Страница 160: ...Figure 7 81 Figure 7 82 Please refer to the following sheet for detailed information...
Страница 198: ...Here one gateway of Ethernet1 is set as 10 15 0 1 And gateway of Ethernet2 is set as 192 168 1 1...