- 19
-
5.
Install housing.
Connect cables through the top hole of the
housing, and then turn the housing thread pipe
head into suspender and fasten the connection
with two M5 screws
NOTE: Apply water-proof tape to the thread in
the case of outdoor dome. If installation height is
not high enough, mount housing directly into the
base.
Tape
Screw
Tape
Screw
6.
Connect cables.
Plug cables into corresponding sockets on circuit
board. Reinstall the circuit board and turn on the
power. The red LED is on if connections are
correct. Turn off the power after checking.
NOTE: Names of the interfaces are marked on
terminal block or PCB. Connect cables as picture
shows. Make sure power is off before connecting.
ALARM
VI DEO
RS485, AC24V
7.
Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
S W 1
S W 2
8.
Lower cover preliminary installation.
Attach the safety chain with a M3 nut as picture
shows.
lube
M4 slot