background image

 

Copyright 2005                                                                                    

21

                                

Vulcan V SERIES

 

 Owner’s Manual 

Canadian Comfort Industries                                      

www.stovesunlimited.com

                                                     Dansons Group Inc. 

 

T

HE 

C

ONTROLS   

 CONTINUED

  

 

TRIM POTS (Fine Tune Adjustments)

– Factory Settings  

 

The 

COMBUSTION

 

FAN (FAN),

 

HI (4) and

 

LO (1) FEED RATE trim pots

 have been preset at the 

factory, but may need to be adjusted onsite after your installation is complete.  Due to different 
installation setups, length and size of venting, and pellet fuel quality, the preset from the factory will 
not always be correct.  These settings will accommodate virtually all wood pellet fuels.  

 

FUEL FEED 

rates

 at the Lowest (number 1) and highest (number 4) settings can be adjusted by 

adjusting the fine tune trim pots located on the control panel.  To 

raise fuel feed

 turn trim pot 

counter clockwise

 and to 

lower 

turn 

clockwise

. To assist in knowing what the change is you 

should note the amount of time the light on the AUGER CYCLE LED stays OFF. 

(Note: The light 

stays on when ever the fuel feed motor, AUGER CYCLE, is running).

 

Lengthening the time this 

LED stays OFF lowers the fuel feed and shortening the off-time increases the fuel feed

.

  

 

COMBUSTION FAN SPEED (FAN) 

In a few instances because of prevailing conditions pertinent to your specific installation, or even 
different batches of pellet fuel, the 

COMBUSTION FAN SPEED

 may be adjusted to raise or lower 

the amount of air moving through the grate for the cleanest burn. The FAN speed can be adjusted 
by adjusting the 

FAN

 trim pot 

COUNTER CLOCKWISE to INCREASE

 

the speed and 

CLOCKWISE to DECREASE

 the speed 

of the combustion fan.  

 

Note: If you attempt to adjust the Fuel Feed Trim Pots, use a small precision screwdriver.  
         The Trim Pots do not make a full rotation.    
          If using a metal screwdriver, be gentle as the plastic trim pot slot can be damaged or stripped.  

 

FAN SPEED

  (Convection or heating)  

The 

FAN SPEED

 controls the speed of the room air fan.  This fan blows room air through the heat 

exchange tubes and back into the room.  The FAN SPEED has 5 different speeds, these are 
controlled by pushing the FAN SPEED touch pad. The Low LED will be solid when on the lowest fan 
speed, the LOW & MED will both be solid when the next highest speed is selected and so on. .When 
the 

FEED RATE

 is set to a higher position, the 

FAN SPEED

 should be set higher and visa versa.  

When the 

FEED RATE

 is set at [3 OR 4] set the

 FAN SPEED

 to [MED/HIGH]. If you forget, the room 

air fan's (L140) temperature limit snap switch automatically sets the fan on high when your stove is 
producing heat faster than the fan is carrying it into the room.  This may occur when the heat control 
lever is set at [3 or 4] and the

 FAN SPEED

 is set to a very low or off setting.  After the fan runs at this 

automatic high setting a few minutes, it may cycle back to its lower setting and may continue to cycle 
between [HIGH ] and your selected setting.  The circulation (room air) fan cycling

 from high to low is 

a normal condition, as well as a safety feature of your appliance. 

 

AUGER CYCLE 

The 

AUGER CYCLE

 LED indicates when a electrical signal is being sent to the auger motor.  It is 

NOT used to indicate the actual movement of the auger.  When the signal is being sent the LED will 
be solid for 3 seconds. When the LED is off no signal is being sent

.  

   
 

S

HUTTING THE STOVE 

OFF 

 

Note:

 DO NOT UNPLUG your stove if there is a fire going or if the stove is still active.  This could result in smoke coming back 

into the room.  Remember the EXHAUST FAN is needed to force the exhaust out of the stove. 
 
On the CCI “AcuTron” Board firmly touch the 

OFF

 touch pad.  The 

FUEL RATE

 LED will turn off.  The 

AUGER CYCLE

 LED will 

turn off.  The auger will stop feeding fuel to the fire and the 

FAN

 speed LED will flash indicating that the appliance is in the “Shut 

Down” mode.  The fire will go out and  the fans will continue to run until your stove cools down at which time the fans will 
automatically shut off and NO LED’s will remain ON. 

HI

MED

LOW

  FAN SPEED

OFF

FAN

SPEED

AUGER

CYCLE

FINE TUNE ADJUSTMENTS

1

4

FAN

Increase

Decrease

Содержание CC2

Страница 1: ......

Страница 2: ...ompany to company from load to load and occasionally from bag to bag 4 Be extra diligent in your cleaning program 5 Remember that most operational dilemmas with a pellet stove are usually traced back...

Страница 3: ...ATION 16 VERTICAL INSTALLATIONS 17 MOBILE HOME INSTALLATION 18 OPERATION LIGHTING A FIRE 19 THE ACUTRON CONTROLS 20 SHUTTING THE STOVE OFF 21 ACUTRON WALL THERMOSTAT OPTIONAL 22 INITIAL BURN SETUP 23...

Страница 4: ...he heater This heater is designed and approved for pelletized wood fuel only Any other type of fuel burned in this heater will void the warranty and safety listing Keep foreign objects out of the hopp...

Страница 5: ...uch Pad does not disconnect all power to the heater BEFORE carrying out any maintenance or cleaning allow the heater to cool Ashes must be disposed in a metal container with a tight lid and placed on...

Страница 6: ...Copyright 2005 6 Vulcan V SERIES Owner s Manual Canadian Comfort Industries www stovesunlimited com Dansons Group Inc...

Страница 7: ...ion as well as a safety feature of your appliance To compensate for the fan cycling adjust the FAN SPEED to a higher setting L250 HIGH LIMIT SWITCH Your pellet appliance has a high temperature limit s...

Страница 8: ...the circuit board will be voided if surge protection is not installed before operating this unit FUEL CONSIDERATIONS Your VULCAN V Series shop and home heater is designed to burn pellets that comply w...

Страница 9: ...INSTALLING YOUR PELLET APPLIANCE _____ Carefully read the ENTIRE installation section first _____ Read the Freestanding or Insert or Built In section which ever applies _____ Determine the location a...

Страница 10: ...and the HE 120 VULCAN V Series 150 figure 2 The V 130 and V 150 product allows you to choose from black painted gold or pewter plated large view door and you can choose black gold or pewter finished...

Страница 11: ...ce It is recommended that at least 3 of vertical pipe be installed to create some natural draft This is to help prevent the possibility of smoke or odor during the appliance shut down Horizontal secti...

Страница 12: ...al Seal Plate or Wall Thimble at point A Figure 7 Figure 8 VENT TERMINATION CLEARANCES Horizontal terminations must protrude 12 from the wall vertical terminations 24 Figure 9 A Minimum 4 clearance be...

Страница 13: ...is installed through the side of a building Keep the outside air pipe termination at least 1 foot away from the exhaust system termination When outside air is taken from an existing chimney the exhaus...

Страница 14: ...evel secure floor The stove must be installed on a non combustible floor protector i e sheet steel with cement tile slate extending the full width and depth of the stove and extending 6 in front of th...

Страница 15: ...ION continued CLEARANCES CORNER INSTALLATION Figure 14 Figure 15 Note If interior vertical vent is used the clearance to the back wall is determined by the upward turned elbow or Tee It will vary in d...

Страница 16: ...sert the proper size of PL vent E through the wall thimble F 5 Place your stove on the floor pad close to its final position Leave room to connect the PL vent to Quick Connect end collar If not alread...

Страница 17: ...Copyright 2005 17 Vulcan V SERIES Owner s Manual Canadian Comfort Industries www stovesunlimited com Dansons Group Inc...

Страница 18: ...or the pedestal to the steel frame of the home Use a number 8 gauge copper wire B figure 26 or equivalent The stove must have a permanent outside air source with a inch screen over the inlet Figure 25...

Страница 19: ...d the FAN SPEED to your desired settings you require upon completion of startup sequence 1 Push firmly on the FEED RATE or START touch pad The COMBUSTION FAN exhaust will start and operate at full spe...

Страница 20: ...d by setting the FEED RATE higher combustion air is automatically increased and visa versa HOW THE BOARD WORKS INITIAL START OR SET UP MANUAL OR NON THERMOSTAT MODE Upon initial start up the control w...

Страница 21: ...oom air through the heat exchange tubes and back into the room The FAN SPEED has 5 different speeds these are controlled by pushing the FAN SPEED touch pad The Low LED will be solid when on the lowest...

Страница 22: ...light up depending on if the thermostat is calling for heat or not When the desired room temperature is reached the stove will automatically go into the low heat 1 cycle When the temperature in the ro...

Страница 23: ...he best way to set this is at the FUEL SETTING 4 When you are pleased with the burn and how the appliance is operating you are now ready to set the board up at LOW setting Set FUEL RATE to 1 or LOW se...

Страница 24: ...p of the flame you need more combustion air Continue to pull out the damper about a 1 8 at a time opening the damper as needed to obtain a flame that is yellow and a fire that is brisk enough to carry...

Страница 25: ...h type of fuel used FACTORS EFFECTING PELLET FEED RATES Generally the smaller harder and cleaner free from fines the pellets are the faster they will feed at a given setting and visa versa The extreme...

Страница 26: ...ellets may experience days or even weeks of burning without the need to remove any clinkers from the grate FINES FINES in pellets are pieces of sawdust that were not properly formed or are the results...

Страница 27: ...to grate bottom or sides Ensure that the holes are clean and unrestricted CAUTION When replacing the grate make sure it fits properly in the burn pot with the lip on the burn grate toward the front of...

Страница 28: ...tom back and front Check periodically for fly ash build up B SUPER GRATE Stainless steel construction slotted bottom and air holes on front and back Slotted hole for Igniter air flow C Adjustment Tab...

Страница 29: ...grate has become plugged with hard residue from burning lower quality fuel you may need to use a sharp awl or drill bit to open holes back to their original size BURN POT This is the pot where the pe...

Страница 30: ...ck Stove Bright paint Tip use a hair dryer to warm the surface prior to touching up the paint this helps to reduce paint runs Note Do not use any other brand than Stove Bright as they may not be compa...

Страница 31: ...or service Fire goes out Fans will not run Check to see that your stove is plugged in and electricity is flowing when START from the electrical outlet button is pushed Check with your VULCAN V Series...

Страница 32: ...TRIES INC This can be done online at www dansons com support All claims under this limited warranty must be made through the dealer where your heater was purchased If an inspection by the dealer indic...

Страница 33: ...C Acu Tron Wall Thermostat Kit USA Includes Thermostat module wall thermostat and 25 18 gauge bell wire Fahrenheit ACWTKTF Small View Shop Door Assembly Black large pin AHDRBAS Large View Door Assembl...

Страница 34: ...ew Neo Ceramic Large View etched Cheap Charlie logo AGNCGE Grates Grate Super Grate ACSLGR Kits Dealers Parts Kit CCI100 Board 1of each fan motor AGDPKTSB timers igniter board electrical switches and...

Страница 35: ...ccess panel 3 Unscrew the control board from the side of the heater 2 x hex screws 4 Locate the thermostat terminal block marked T STAT INPUT found on the back of the board see figure 31 5 Be sure to...

Страница 36: ...ad Screwdriver Pail or bin How to Install 1 Unplug the appliance power cord from the wall outlet 2 To gain access to the inside of the appliance remove the hex screws from the LEFT HAND SIDE PANEL loo...

Страница 37: ...ROV CITY STATE PROV CONTACT PHONE ZIP PC PHONE PURCHASE DATE INSTALL DATE INSTALLED BY STOVE MODEL SERIAL NUMBER WAS UNIT PRE BURNED SPECIAL COMMENTS MAINTENANCE LOG SERVICE DATE TECHNICIAN DESCRIPTIO...

Отзывы: