Copyright 2005
14
Vulcan V SERIES
Owner’s Manual
Canadian Comfort Industries
www.stovesunlimited.com
Dansons Group Inc.
6”
1”
10”
6”
1”
10”
12”
T
HROUGH
T
HE
W
ALL
6”
3”
10”
I
NTERIOR
V
ERTICAL
F
REESTANDING
I
NSTALLATION
HEATER PLACEMENT:
Stove must be placed so that no combustibles are within, or can swing within (i.e. drapes doors),
36” of the heater.
If the stove is placed in a location where the ceiling height is less than 7’, it must follow the
requirements in the section “Alcove Installation”.
FLOOR PROTECTION REQUIREMENTS:
Stove and floor protection must be installed on a level secure floor
The stove must be installed on a non-combustible floor protector (i.e. sheet steel with cement, tile
slate) extending the full width and depth of the stove and extending 6” in front of the stove. Floor
protector needs to be a minimum of 24.5” deep X 30.5” wide and be a minimum of .018” thick (26
gauge).
Must extend under and 2” to each side of chimney tee (if used).
MINIMUM CLEARANCES TO COMBUSTIBLES
(Figures 12-17)
1” From Back Of Heater to Combustibles
3” From PL Vent to Combustibles
10” From Front Side of Heater to Combustibles
1” From Back Corner of Heater to Combustibles
6” Non Combustible Surface In Front Of Heater
16” From Top Of Heater to Combustibles
36” to drapes, doors, anything that can swing
CLEARANCES – “STRAIGHT INSTALLATION”:
Figure 12
Figure 13
Содержание CC2