D2-10 Series Two-Post Lifts
56
P/N 5900249 — Rev. B — February 2021
Approved Hydraulic Fluids are any general purpose ISO-32, ISO-46, or ISO-68 hydraulic oil or
approved automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, Shell
Tellus S4 / S3 / S2, or any synthetic multi-vehicle automatic transmission fluid.
⚠
WARNING
Do not run the Power Unit without Hydraulic Fluid; you will damage it.
Important electrical information:
Improper elec
trical installation can damage the Power Unit motor; this damage is
not
covered by the
warranty.
Use a separate circuit breaker for each Power Unit.
Protect each circuit with a time-del
ay fuse or circuit breaker.
–
For a 220 VAC, single phase circuit, use a 25 amp or greater fuse.
–
For a 208-230 VAC three phase circuit, use a 20 amp or greater fuse.
–
For a 380 or 440 VAC three phase circuit, use a 15 amp fuse.
As you require an Electrician on site to connect the Power Unit to a power source, you might also
want to have them install the Power Disconnect Switch and the Thermal Disconnect Switch on the
same visit.
⚠
DANGER
Risk of explosion: This equipment has internal arcing or parts that may spark and
should not be exposed to flammable vapors. The Power Unit’s motor should not be
located in a recessed area or below floor level. Never expose the motor to rain or
other damp environments; damage to the motor caused by water is not covered by
the warranty.
Installing a Power Disconnect Switch
⚠
WARNING
A Power Disconnect Switch is not provided with
this equipment.
A Power Disconnect Switch is a National Electrical Code (NEC)
requirement. They are designed to interrupt main electrical power in
the event of an electrical circuit fault, emergency situation, or when
equipment is undergoing service or maintenance.
Make sure to install a Power Disconnect Switch that is properly
rated for the incoming power source.
Your Power Disconnect Switch must be readily accessible and
installed so that it is in easy reach of the operator or in their line of
sight. The Power Disconnect Switch must be clearly marked to
indicate its purpose.
The figure to the right shows a toggle-style Power Disconnect
Switch located between the Lift’s power source and its Power Unit.
A quick flip of the switch immediately cuts power to the Lift.
Have the Electrician select a
UL-listed
Power Disconnect Switch.
Содержание D2-10 Series
Страница 11: ...D2 10 Series Two Post Lifts 11 P N 5900249 Rev B February 2021 D2 10A Specifications ...
Страница 12: ...D2 10 Series Two Post Lifts 12 P N 5900249 Rev B February 2021 D2 10C Specifications ...
Страница 72: ...D2 10 Series Two Post Lifts 72 P N 5900249 Rev B February 2021 Labels ...
Страница 73: ...D2 10 Series Two Post Lifts 73 P N 5900249 Rev B February 2021 ...
Страница 74: ...D2 10 Series Two Post Lifts 74 P N 5900249 Rev B February 2021 ...
Страница 75: ...D2 10 Series Two Post Lifts 75 P N 5900249 Rev B February 2021 ...
Страница 76: ...D2 10 Series Two Post Lifts 76 P N 5900249 Rev B February 2021 Parts Drawings ...
Страница 77: ...D2 10 Series Two Post Lifts 77 P N 5900249 Rev B February 2021 ...
Страница 78: ...D2 10 Series Two Post Lifts 78 P N 5900249 Rev B February 2021 ...
Страница 79: ...D2 10 Series Two Post Lifts 79 P N 5900249 Rev B February 2021 ...
Страница 80: ...D2 10 Series Two Post Lifts 80 P N 5900249 Rev B February 2021 ...
Страница 81: ...D2 10 Series Two Post Lifts 81 P N 5900249 Rev B February 2021 ...
Страница 82: ...D2 10 Series Two Post Lifts 82 P N 5900249 Rev B February 2021 ...
Страница 84: ...D2 10 Series Two Post Lifts 84 P N 5900249 Rev B February 2021 Maintenance Log ...
Страница 85: ...D2 10 Series Two Post Lifts 85 P N 5900249 Rev B February 2021 Maintenance Log ...
Страница 86: ...D2 10 Series Two Post Lifts 86 P N 5900249 Rev B February 2021 Maintenance Log ...
Страница 87: ...D2 10 Series Two Post Lifts 87 P N 5900249 Rev B February 2021 Maintenance Log ...
Страница 88: ...1645 Lemonwood Drive Santa Paula CA 93060 USA 2021 by BendPak Inc All rights reserved dannmar com ...