5. Configuration

Before making input, output and GPIO connections, 
an initial Danley DSA amplifier configuration should 
be established. It is particularly important that the 
amplifier output  format is configured appropriately for 
the speakers that are to be connected.

Configuration requires that  Danley DSA amplifiers are 

connected to mains power, switched on and connected 

to network services. These connections are described in 
the following two sections.

5.1 Mains Power Connection

Danley DSA amplifiers incorporate a power factor corrected 
power supply and can be used with mains input voltage from 
100V AC to 240V AC, 50/60Hz. Use the mains cable supplied 
with the amplifier and connect it to a mains supply.

Press the front panel power button to switch on the amplifier. 
After a short delay the front panel Status indicator will 

illuminate green.

5.2 Network Services

Danley DSA amplifiers are configured via the  Control 
Web App interface. Before the Web App configuration 
menus can be accessed, Danley DSA amplifiers must be 
connected to the same TCP/IP network as the computer 
or mobile device that is to be used for configuration.

5.2.1 Wired (Ethernet) Network Connection

To connect a  Danley DSA amplifier to a TCP/IP network using a 
wired connection (Ethernet) follow the steps below.

1.

 Use an Ethernet cable to connect the  Danley DSA amplifier 

rear panel Network Control socket to a free socket on a 
network router or switch, or directly to an Ethernet equipped 
laptop or desktop computer.

2. Connect the  Danley DSA amplifier to mains power using 
the supplied mains cable. Wait for the front panel Network 
indicator to illuminate green to indicate that the amplifier has 
network connectivity.

3. The Danley DSA amplifier default LAN IP address is 
192.168.64.100. Configure the laptop or desktop computer 
for a fixed IP address in the same IP range; eg. 192.168.64.10, 
with Subnet mask of 255.255.255.0 (or prefix 24) and set the 
Gateway to 192.168.64.1.

4. Open a laptop or desktop web browser and enter the address 

http://192.168.64.100. The  Control Web App interface will 
open to enable amplifier configuration as required.

Note: Danley DSA amplifiers can be configured to use DHCP for 
network connection if required. However, if a  Danley DSA amplifier 
using DHCP is power cycled, it is possible that the TCP/IP network 
router will assign it a different IP address, leaving its configuration 
page inaccessible via the previous address. If this occurs, a network 
scanning app can be used to identify the new IP address. DHCP and 
Fixed IP address option settings can be found in the Settings Tab 
menu described in Section 5.3.   

5.2.2 Wireless (WiFi) Network Connection

To connect a  Danley DSA amplifier to a TCP/IP network using a 
wireless connection (WiFi) follow the steps below.

1.

 With the Danley DSA amplifier connected to mains power, 

wait for the front panel WiFi indicator to illuminate green.

2.

 Use a mobile, laptop or desktop device to search for available 

WiFi networks. Connect to, Danley DSA (product serial 
number)’ using the password,

 ‘password’.

 The amplifier serial 

number can be found on its rear panel.

3.

 Open a computer or mobile device web browser and enter 

the IP address: 192.168.4.1. The  Control Web App interface 
will open to enable amplifier configuration as required. 

4. 

Select the Web App Settings Tab followed by WiFi > WiFi 

Mode > Client to configure the amplifier to connect to the 
required WiFI network. The WiFi network name and password 
will be required. 

It is strongly recommended that the  Danley DSA amplifier 

Access Point WiFi password is changed following initial 

wireless connection.

Содержание DSA500X4

Страница 1: ...INSTALLATION GUIDE USER MANUAL DSA500X4 DSA750X4 Rev 20220706...

Страница 2: ...vel of performance and in good operating condition Any damage to or unsatisfactory performance from these amplifiers caused by inadequate or failed input or output ancillaries may invalidate support w...

Страница 3: ...particularly at plugs convenience receptacles and the point where they exit from the apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specifi...

Страница 4: ...Overview Danley DSA500X4 and DSA750X4 amplifiers are a full rack width 2U format power amplifiers that can drive both conventional low impedance Lo Z 4 to 16 loudspeakers and high impedance Hi Z 70V 1...

Страница 5: ...eb App interface and cover Input Zone Output and General Settings functions The Control web app configuration menus are described in Section 5 of this manual 2 3 Firmware This manual describes the fea...

Страница 6: ...d are primarily intended for standard 19 inch equipment rack installation If not to be installed in an equipment rack Danley DSA amplifiers can be placed free standing on a flat surface Adhesive rubbe...

Страница 7: ...ectivity 3 The Danley DSA amplifier default LAN IP address is 192 168 64 100 Configure the laptop or desktop computer for a fixed IP address in the same IP range eg 192 168 64 10 with Subnet mask of 2...

Страница 8: ...sitivity option Adjust input gain Adjust zone volume Adjust zone volume Note When adjusting input gain the input level display should remain green If it displays red the input gain should be reduced 5...

Страница 9: ...b menus For all Output Tab menus the amplifier output under configuration is selected by highlighting one of the output identifiers 1 2 3 or 4 at the top of the display The Output Tab also enables Spe...

Страница 10: ...d in Section 5 3 5 2 Select the appropriate zcp format speaker preset data file to import from either a Library or a computer folder The preset data will be applied to the selected amplifier output as...

Страница 11: ...s filter settings The Output Mode preset menu enables individual amplifier outputs to be switched off or configured for Lo Z Hi Z or Lo Z BTL modes In Hi Z modes a high pass filter can also be configu...

Страница 12: ...menu enables amplifier configuration data to be downloaded to an external archive and enables previously saved configuration files to be uploaded and adopted by the currently connected amplifier The S...

Страница 13: ...Gain Trim Gain Trim Gain Trim Input Sensitivity Input Gain Input Gain Input Selection Input Setup Zone Setup Routing Output Setup Output 1 Output 2 Output 3 Output 4 Zone Adjustment Parameters Speaker...

Страница 14: ...e zone to be configured The number of zones available and their channel format stereo or mono will depend on the amplifier model input setup and output mode Lo Z or Hi Z For example a two output ampli...

Страница 15: ...in 8 has a low output impedance and is able to supply a maximum current of 10mA Note GPIO Pin 1 and Pin 3 both offer ground connections Pin 1 is connected directly to the amplifier chassis Pin 3 is co...

Страница 16: ...DSA rear panel connections Note Two output amplifier model connection sockets differ only in the deletion of channel 3 and channel 4 output connectors Digital Inputs Danley DSA S PDIF stereo digital a...

Страница 17: ...ble Length Metres 1500 W channel 0 75 18 50 30 1 5 16 100 60 2 0 14 160 100 3 5 12 250 160 Connections 6 4 Speaker Cable Gauge Danley DSA speaker connection cable gauge should be chosen appropriately...

Страница 18: ...5 mm Connections Diagram 6b Balanced analog input cable connections Diagram 6c Output cable connections Low Z Mode Hi Z BTL Modes 5 mm 5 mm...

Страница 19: ...s is in addition to the CLASS 2 WIRING text intended to alert users to the risk of hazardous voltages Output connectors that could pose a risk are marked with the exclamation point Do not touch the ou...

Страница 20: ...anley DSA amplifier front panel indicators illuminate to indi cate the following operational states Status Off Mains power disconnected Green Amplifier operational Pulse Green Standby Mode Amber GPIO...

Страница 21: ...8 x 440 x 332 mm 3 5 x 17 3 x 13 1 in Output Circuitry UMAC Class D full bandwidth PWM modulator with ultra low distortion Signal To Noise Ratio 108 dB A weighted 20 Hz 20 kHz 8 load THD N typical 0 0...

Отзывы: