Operation
7. Operation
Once all connections have been made and configuration
options selected, Danley DSA amplifiers are ready for
use. If an input signal above -60dB is present on any
input, the front panel Input and Standby indicators will
illuminate green to indicate normal amplifier operation.
Audio will be heard from any connected speakers.
Note: Danley DSA amplifiers will by default not wake from Standby
Mode unless an input signal is present, a network ‘ON’ command is
received, or an external standby switch (or 12V trigger) is operated.
Standby behaviour can be configured via the Power Management
menu of the Control Web App Settings Tab.
Amplifier outputs will mute if no input signal is present for 5
minutes, and the amplifier will switch automatically to Standby
Mode if no signal is present on any input for more than 15
minutes. Alternative standby and mute delay times can selected
via the
Settings Tab
. Amplifier cooling fan speed is temperature
controlled. The fan will switch off when the amplifier enters
standby mode.
7.1 Front Panel Indicators
Danley DSA amplifier front panel indicators illuminate to indi-
cate the following operational states:
Status:
Off – Mains power disconnected.
Green – Amplifier operational.
Pulse Green – Standby Mode.
Amber – GPIO triggered Standby Mode
Input:
Off – No input signal present.
Green – Signal present on one or more inputs.
Amber – Signal limiting/clipping on one or more
inputs.
Output:
Off – No output signal present.
Green – Signal present on one or more outputs.
Amber – Signal limiting/clipping on one or more
outputs.
Red – One or more channel pair is in
overload/protection mode.
Network:
Off – No Ethernet network detected.
Green – Ethernet network detected.
WiFi:
Off – WiFi disabled.
Green – WiFi enabled.
7.2 Default Reset
Danley DSA amplifiers can be returned to their default settings
via either the Control Web App
Settings Tab
or through the
front panel power button.
To reset the amplifier using the front panel power button,
follow the steps below:
• Disconnect the amplifier from mains power.
• Press and hold the front panel power button while
simultaneously reconnecting mains power.
• Continue to hold the front panel power button for 3 to 5
seconds as the amplifier restarts.
The amplifier will restart with all settings at their default state.