Installation
4. Installation
Note: The rack mounting and desk/wall mounting components
described and illustrated in Sections 4.1 to 4.3 are not supplied with
Danley DSA amplifiers but are available to purchase as accessories.
Contact your amplifier re-seller for more information.
4.1 Danley DSA Mounting
The
Danley DSA
amplifiers are shipped without rack mount
hardware attached but can be configured for rack installation
using one standard rack ‘ear’ and one half-rack extension piece
as illustrated in
Diagram 3a
. The installation and equipment
rack should be configured to provide appropriate ventilation
airflow space around the sides and rear of the amplifier as
illustrated in as illustrated in
Diagram 1a
. Ventilation airflow
space of at least 25 mm (1 in) should be maintained along at
least one side of the amplifier at all times. Ventilation apertures
are also located on the rear panel of the amplifier and must not
be obstructed. It is important to retain at least 80 mm (3.1 in)
free space for airflow behind the amplifier rear panel.
In addition to rack mount ears, optional rack mount rear
support hardware is available and can be attached to the
amplifier. Rear support hardware may be appropriate if
the amplifier is to be used in a mobile rack or potentially be
subject to significant movement.
Diagram 3b
illustrates the
use of rack mount rear support hardware.
Multiple
Danley DSA
amplifiers can also be mechanically
connected using accessory connecting plates.
Diagram 3c
illustrates the use of connecting plates.
Diagram 3a
Danley DSA
Rack Ear + Half-rack Extension.
Diagram 3b
Danley DSA
Rack Support hardware. 2 positions.
Rack Ear +
2 x M4 x 8
countersunk
Half-rack Ext
2 x M4 x 8 countersunk
Rear S
1 x M4 x 8
Connection Plate +
4 x M3 x 6 countersunk
Diagram 3c
2 x Danley DSA with Connection Plate. 2
positions