manualshive.com logo in svg
background image

Introduction and Overview

1. Introduction

 Danley DSA power amplifiers have been designed 
to provide configurable, consistent and reliable high 
performance audio power amplification for residential, 
commercial and entertainment applications. Please 

read this manual fully before installing and using an 

amplifier. If you have any questions regarding amplifier 
configuration, installation or operation please contact 
the appropriate customer support portal.

Following this introduction, the manual is divided into sections 
covering the following topics:

• 2. Overview 

 

• 3. Carton Contents

 

• 4. Installation

 

• 5. Configuration

 

• 6. Connections

 

• 7. Operation 

• 8. Specifications 

2. Amplifier Overview

Danley 

DSA125X4 

amplifiers are half rack width, 1U format 

power amplifiers that can drive both conventional low 
impedance (Lo-Z, 4Ω to 16Ω) loudspeakers and high impedance 
(Hi-Z, 70V/100V) transformer coupled loudspeakers. They 

provide

 

four analog inputs, one stereo S/PDIF digital input, and 

either two or four outputs (Lo-Z mode), or one or two outputs 
(Hi-Z mode). Danley DSA amplifiers also incorporate automatic 
power sharing technology that enables power to be shared 
proportionately as required between pairs of outputs in Lo-Z 
mode. Danley DSA amplifier model output channel counts and 
power outputs are as follows:

DSA125X4 

Mode 

Channels 

Max Rated Output per Channel 

Lo-Z 

Four 

125 Watts

 

Hi-Z 

Two 

250 Watts

Содержание DSA125X4

Страница 1: ...INSTALLATION GUIDE USER MANUAL DSA125X4 Rev 20220706...

Страница 2: ...vel of performance and in good operating condition Any damage to or unsatisfactory performance from these amplifiers caused by inadequate or failed input or output ancillaries may invalidate support w...

Страница 3: ...particularly at plugs convenience receptacles and the point where they exit from the apparatus 14 Do not unplug the unit by pulling on the cord use the plug 15 Only use attachments accessories specifi...

Страница 4: ...ation 5 Configuration 6 Connections 7 Operation 8 Specifications 2 Amplifier Overview Danley DSA125X4 amplifiers are half rack width 1U format power amplifiers that can drive both conventional low imp...

Страница 5: ...iers are primarily intended for installation in an equipment rack but can also be under desk or wall mounted or used free standing They are fan cooled and must be installed such that ventilation apert...

Страница 6: ...Shaded area defines ventilation space Diagram 1a Danley DSA two channel amplifier dimensions Shaded area defines ventilation space 44 mm 1 7 in 44 mm 1 7 in 220 mm 8 7 in 220 mm 8 7 in 213 mm 8 4 in 8...

Страница 7: ...ier at all times Ventilation apertures are also located on the rear panel of the amplifier and must not be obstructed It is important to retain at least 80 mm 3 1 in free space for airflow behind the...

Страница 8: ...unted using connecting plate hardware The adhesive rubber feet should also be used in these circumstances to minimise the possibility of vibration between the amplifier and mounting surface Wall and d...

Страница 9: ...mplifier default LAN IP address is 192 168 64 100 Configure the laptop or desktop computer for a fixed IP address in the same IP range eg 192 168 64 10 with Subnet mask of 255 255 255 0 or prefix 24 a...

Страница 10: ...ity option Adjust input gain Adjust zone volume Adjust zone volume Note When adjusting input gain the input level display should remain green If it displays red the input gain should be reduced 5 3 Co...

Страница 11: ...b menus For all Output Tab menus the amplifier output under configuration is selected by highlighting one of the output identifiers 1 2 3 or 4 at the top of the display The Output Tab also enables Spe...

Страница 12: ...d in Section 5 3 5 2 Select the appropriate zcp format speaker preset data file to import from either a Library or a computer folder The preset data will be applied to the selected amplifier output as...

Страница 13: ...arameters adjust automatically in response to Crossover Gain high pass filter settings The Output Mode preset menu enables individual amplifier outputs to be switched off or configured for Lo Z or Hi...

Страница 14: ...nder the Device menu The Backup Restore menu enables amplifier configuration data to be downloaded to an external archive and enables previously saved configuration files to be uploaded and adopted by...

Страница 15: ...Gain Trim Gain Trim Gain Trim Input Sensitivity Input Gain Input Gain Input Selection Input Setup Zone Setup Routing Output Setup Output 1 Output 2 Output 3 Output 4 Zone Adjustment Parameters Speake...

Страница 16: ...elect the zone to be configured The number of zones available and their channel format stereo or mono will depend on the amplifier model input setup and output mode Lo Z or Hi Z For example a two outp...

Страница 17: ...in 8 has a low output impedance and is able to supply a maximum current of 10mA Note GPIO Pin 1 and Pin 3 both offer ground connections Pin 1 is connected directly to the amplifier chassis Pin 3 is co...

Страница 18: ...ions Note Two output amplifier model connection sockets differ only in the deletion of channel 3 and channel 4 output connectors Digital Inputs Danley DSA amplifier S PDIF stereo digital audio input c...

Страница 19: ...A amplifiers to a TCP IP network is described in Section 5 of this manual Cable Gauge Table Lo Z installations 0 5dB attenuation 4 8 loads Cable Gauge Table 70V Hi Z installations 1 0dB attenuation 20...

Страница 20: ...e exclamation point printed next to the output terminals of the amplifiers is in addition to the CLASS 2 WIRING text intended to alert users to the risk of hazardous voltages Output connectors that co...

Страница 21: ...ts Output Off No output signal present Green Signal present on one or more outputs Amber Signal limiting clipping on one or more outputs Red One or more channel pair is in overload protection mode Net...

Страница 22: ...0Hz 20kHz 8 load THD N typical 0 05 20Hz 20kHz 8 load 3dB below rated power Frequency Response 20Hz 20kHz 0 0 25dB 8 load 3dB below rated power Protection Circuits Short circuit DC Undervoltage Temper...

Отзывы: