8.1.1 Mains Supply 3x525-690 V AC
N
o
rmal
o
v
e
rl
o
ad
110%
fo
r 1
minute
Si
ze:
P
11K
P15K
P
18K
P22K
P
30K
P37K
P45K
P
55K
P75K
P90K
Typical
Sh
af
t Output
[kW
]
11
15
18.5
2
2
3
0
3
7
4
5
5
5
7
5
9
0
Typical
Sh
af
t Output
[HP]
at
575
V
1
0
16.4
20.1
2
4
3
3
4
0
5
0
6
0
7
5
100
IP
2
1
/N
E
M
A
1
B
2B
2B
2
B
2
B
2
C
2
C
2
C
2
C
2
C
2
IP55/NEMA
12
B2
B2
B
2
B2
B2
C2
C2
C2
C2
C2
Ou
tp
u
t c
u
rr
en
t
Co
n
tin
uo
u
s
(3x
525-550
V)
[A]
14
19
23
28
36
43
54
65
87
105
In
te
rm
itten
t
(3x
525-550
V)
[A]
15.4
20.9
25.3
30.8
39.6
47.3
59.
4
71.5
95.7
115.
5
Co
n
tin
uo
u
s
(3x
551-690
V)
[A]
13
18
22
27
34
41
52
62
83
100
In
te
rm
itten
t
(3x
551-690
V)
[A]
14.3
19.8
24.2
29.7
37.4
45.1
57.
2
68.2
91.3
110
C
o
ntinuous
k
V
A
(550
V
AC)
[k
V
A
]
13.3
18.1
21.9
26.7
34.3
4
1
51.
4
61.9
82.9
100
C
o
ntinuous
k
V
A
(575
V
AC)
[k
V
A
]
12.9
17.9
21.9
26.9
33.8
40.8
51.
8
61.7
82.7
99.6
C
o
ntinuous
k
V
A
(690
V
AC)
[k
V
A
]
15.5
21.5
26.3
32.3
40.6
4
9
62.
1
74.1
99.2
119.
5
Max.
cable
s
ize
(mai
ns
, mot
o
r,
b
rake
)
[mm
2
]/[AWG
]
2)
35
1/0
95
4/0
Max
. input
curr
e
n
t
Co
n
tin
uo
u
s
(3x
525-690
V)
[A]
1
5
1
9
.5
2
42
93
64
95
9
7
1
8
7
9
9
In
te
rm
itten
t
(3x
525-690
V)
[A]
16.5
21.5
26.4
31.9
39.6
53.9
64.
9
78.1
95.7
108.
9
Max.
pr
e
-fus
e
s
1)
[A
]
63
63
63
63
80
100
125
160
160
160
Env
iro
nm
en
t:
Est
ima
te
d
po
wer
lo
ss
at
rat
e
d
ma
x.
l
o
ad
[W]
4)
201
285
335
375
430
592
720
880
1200
1440
We
igh
t:
IP
21
[kg]
27
27
27
27
27
65
65
65
65
65
IP
55
[kg]
27
27
27
27
27
65
65
65
65
65
E
ff
ici
en
cy
4)
0.98
0.98
0.98
0.98
0.98
0.98
0.
98
0.98
0.98
0.98
1)
F
o
r t
y
p
e
o
f f
u
se
s
e
e
2)
A
m
er
ic
a
n
Wi
re
G
a
ug
e
3)
Me
a
su
red
u
si
n
g
5
m
s
cre
en
ed
mo
to
r c
a
bl
es
at
r
a
te
d
l
o
a
d
a
n
d
ra
te
d
f
requ
e
ncy
4)
T
h
e t
y
p
ic
a
l p
o
w
e
r l
o
ss
i
s
a
t n
o
rm
a
l l
o
a
d
c
o
n
d
it
io
n
s a
n
d
e
x
p
e
ct
e
d
t
o
b
e
w
it
h
in
+
/-
1
5
%
(
to
le
ra
n
ce
r
e
la
te
s t
o
v
a
ri
e
ty i
n
v
o
lt
a
g
e
an
d
cabl
e
cond
it
ions).
V
a
lu
es
ar
e
b
a
se
d
o
n
a
ty
pi
ca
l m
o
to
r ef
fi
ci
en
cy
. L
o
w
e
r e
ff
ic
ie
n
cy
m
o
tors
wil
l a
lso
a
d
d
t
o
th
e
powe
r loss
i
n
the
fre
q
u
e
nc
y
c
o
n
v
e
rter
a
n
d
vi
ce
versa.
If
t
h
e
s
w
it
ching
fr
eq
ue
ncy
is
rai
sed
fr
om
nom
inal
t
h
e
powe
r los
se
s
ma
y
ri
se
si
gnifi
cant
ly.
L
C
P
and
t
y
pi
ca
l co
nt
ro
l car
d
p
o
wer
c
o
nsum
pt
io
ns
are
incl
uded.
Fu
rt
h
e
r op
ti
on
s
a
n
d
c
u
stom
er
l
o
ad
m
a
y
a
d
d
u
p
to
30
W
to
t
h
e
l
o
sse
s.
(Th
o
ug
h
t
y
p
ica
lly
o
n
ly
4
W
ext
ra
fo
r a
full
y
loa
d
e
d
con
trol
car
d
o
r op
ti
on
s
for
slo
t A
o
r s
lo
t B
, e
a
ch
).
Al
th
ou
g
h
m
e
a
surem
e
n
ts
a
re
m
a
d
e
with
st
at
e
of
the
a
rt
e
q
u
ipm
ent
,
some
me
as
ure
m
e
n
t inacc
u
ra
cy
mus
t be
al
lowe
d
for
(
±
5%).
5)
Motor
and
mains
ca
ble
: 300MC
M
/150
mm
2
T
a
b
le
8.
7
M
a
ins
Su
ppl
y
3x5
2
5
-69
0
V
AC
General Specifications and ...
VLT
®
Refrigeration Drive Design Guide
MG16G102 - VLT
®
is a registered Danfoss trademark
111
8
8