6-18
VLT is a registered Danfoss trademark
6.13 Current Sensor
1.
Remove motor cabling, as required.
2.
Remove input terminal mounting plate assembly
per instructions.
3.
Remove terminals U, V, and W by removing 3
mounting screws. Terminal slides out from under
current sensor.
4.
Disconnect current sensor cable from current
sensor.
5.
Note which cables attach to which sensor for
reasembly. Remove 2 (8mm) retaining nuts from
stud on chassis baseplate and remove sensor.
Reinstall in reverse order of this procedure. Tighten 8mm
mounting nuts to 20 in-lbs (2.25 Nm).
Figure 6-12. Current Sensors
Current sensor
Terminal mounting screws (2)
Output motor cable
connection screws (2)
Terminal mounting screw
Terminal
Current sensor
mounting screws (2)