4.4.4 Changing the Oil
CAUTION
Danger of burns
The surface of the VLT
®
OneGearDrive can reach high
temperatures during operation.
•
Do not touch the VLT
®
OneGearDrive until it has
cooled down.
CAUTION
Danger of burns
The oil in the VLT
®
OneGearDrive reaches high temper-
atures during operation.
•
Do not carry out the oil change until the oil has
cooled down sufficiently.
1
2
130BC424.10
Illustration 4.3 VLT
®
OneGearDrive Oil Screws 1 and 2
Draining the oil
1.
Once the VLT
®
OneGearDrive has cooled down,
remove it from your system
2.
Bring the VLT
®
OneGearDrive into a vertical
position and remove oil screws 1 and 2
3.
Turn the VLT
®
OneGearDrive into a horizontal
position and drain the oil through screw hole 1
into a suitable container
4.
Turn the VLT
®
OneGearDrive back into a vertical
position
Filling the oil
NOTE
The required oil quantities can be found on the nameplate
and in
.
1.
Fill the VLT
®
OneGearDrive with the appropriate
amount of oil through screw hole 1.
2.
Remove all traces of oil from the surface of the
VLT
®
OneGearDrive using a soft cloth.
3.
Re-insert and tighten oil screws 1 and 2.
4.5 Spare Parts
Spare parts can be ordered via the Danfoss VLT Shop:
vltshop.danfoss.com
Service and Maintenance
VLT
®
OneGearDrive Operating Instructions
20