2.11 Three-phase Gear Motors Connection Diagram
CAUTION
Refer to the Operating Instructions for VLT
®
AutomationDrive FC 302 and VLT
®
Decentral Drive FCD 302 to connect the
terminals.
Do not connect the VLT
®
OneGearDrive directly to the power supply.
shows the connection power plug for VLT
®
OneGearDrive Hygienic DA09LA10 in Y-connection with
thermistors.
130BB868.12
V1
W1
U1
U
V
W
2
3
D
C
A
B
1
4
T1
T2
Illustration 2.7 Three-phase Gear Motor Connections
Description
Inverter output
Pin
Typical cross section
Maximum cross section
Motor winding
U
1
AWG 16/1.5 mm
2
AWG 14/2.5 mm
2
V
3
W
4
Protective Earth
PE
2
AWG 16/1.5 mm
2
AWG 14/2.5 mm
2
Temperature protection
1)
KTY 84-130
T1
A
AWG 20/0.75 mm
2
AWG 16/1.5 mm
2
T2
B
Table 2.7 Three-phase Gear Motor Connections
1) When connected to VLT
®
AutomationDrive FC 302 and VLT
®
Decentral Drive FCD 302, use analog input terminal 54, KTY sensor 1. For
information about parameter setting and programming, refer to the corresponding operating instructions.
T1
KTY 84-130
VLT
®
AutomationDrive FC 302
1)
VLT
®
Decentral Drive FCD 302
1)
T2
KTY Sensor 1
Analog Input 54
Table 2.8 Connections T1 and T2
1) Only if connected
Installation
VLT
®
OneGearDrive Operating Instructions
MG75C302 - VLT
®
is a registered Danfoss trademark
13
2
2
Содержание VLT OneGearDrive
Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions VLT OneGearDrive ...
Страница 2: ......
Страница 36: ...www danfoss com drives MG75C302 130R0239 MG75C302 Rev 2013 04 04 ...