15-74

Option

 in

 Slot

 C0

15-75

Slot

 C0

 Option

 SW

 Version

15-76

Option

 in

 Slot

 C1

15-77

Slot

 C1

 Option

 SW

 Version

15-8*

Operating

 Data

 II

15-80

Fan

 Running

 Hours

15-81

Preset

 Fan

 Running

 Hours

15-9*

Parameter

 Info

15-92

Defined

 Parameters

15-93

Modified

 Parameters

15-98

Drive

 Identification

15-99

Parameter

 Metadata

16-**

Data

 Readouts

16-0*

General

 Status

16-00

Control

 Word

16-01

Reference

 [Unit]

16-02

Reference

 [%]

16-03

Status

 Word

16-05

Main

 Actual

 Value

 [%]

16-09

Custom

 Readout

16-1*

Motor

 Status

16-10

Power

 [kW]

16-11

Power

 [hp]

16-12

Motor

 Voltage

16-13

Frequency

16-14

Motor

 Current

16-15

Frequency

 [%]

16-16

Torque

 [Nm]

16-17

Speed

 [RPM]

16-18

Motor

 Thermal

16-22

Torque

 [%]

16-26

Power

 Filtered

 [kW]

16-27

Power

 Filtered

 [hp]

16-3*

Drive

 Status

16-30

DC

 Link

 Voltage

16-32

Brake

 Energy

 /s

16-33

Brake

 Energy

 /2

 min

16-34

Heatsink

 Temp.

16-35

Inverter

 Thermal

16-36

Inv.

 Nom.

 Current

16-37

Inv.

 Max.

 Current

16-38

SL

 Controller

 State

16-39

Control

 Card

 Temp.

16-40

Logging

 Buffer

 Full

16-41

Logging

 Buffer

 Full

16-43

Timed

 Actions

 Status

16-49

Current

 Fault

 Source

16-5*

Ref.

 &

 Feedb.

16-50

External

 Reference

16-52

Feedback

 [Unit]

16-53

Digi

 Pot

 Reference

16-54

Feedback

 1

 [Unit]

16-55

Feedback

 2

 [Unit]

16-56

Feedback

 3

 [Unit]

16-58

PID

 Output

 [%]

16-6*

Inputs

 &

 Outputs

16-60

Digital

 Input

16-61

Terminal

 53

 Switch

 Setting

16-62

Analog

 Input

 53

16-63

Terminal

 54

 Switch

 Setting

16-64

Analog

 Input

 54

16-65

Analog

 Output

 42

 [mA]

16-66

Digital

 Output

 [bin]

16-67

Pulse

 Input

 #29

 [Hz]

16-68

Pulse

 Input

 #33

 [Hz]

16-69

Pulse

 Output

 #27

 [Hz]

16-70

Pulse

 Output

 #29

 [Hz]

16-71

Relay

 Output

 [bin]

16-72

Counter

 A

16-73

Counter

 B

16-75

Analog

 In

 X30/11

16-76

Analog

 In

 X30/12

16-77

Analog

 Out

 X30/8

 [mA]

16-8*

Fieldbus

 &

 FC

 Port

16-80

Fieldbus

 CTW

 1

16-82

Fieldbus

 REF

 1

16-84

Comm.

 Option

 STW

16-85

FC

 Port

 CTW

 1

16-86

FC

 Port

 REF

 1

16-9*

Diagnosis

 Readouts

16-90

Alarm

 Word

16-91

Alarm

 Word

 2

16-92

Warning

 Word

16-93

Warning

 Word

 2

16-94

Ext.

 Status

 Word

16-95

Ext.

 Status

 Word

 2

16-96

Maintenance

 Word

18-**

Info

 &

 Readouts

18-0*

Maintenance

 Log

18-00

Maintenance

 Log:

 Item

18-01

Maintenance

 Log:

 Action

18-02

Maintenance

 Log:

 Time

18-03

Maintenance

 Log:

 Date

 and

 Time

18-1*

Fire

 Mode

 Log

18-10

Fire

 Mode

 Log:

 Event

18-11

Fire

 Mode

 Log:

 Time

18-12

Fire

 Mode

 Log:

 Date

 and

 Time

18-3*

Inputs

 &

 Outputs

18-30

Analog

 Input

 X42/1

18-31

Analog

 Input

 X42/3

18-32

Analog

 Input

 X42/5

18-33

Analog

 Out

 X42/7

 [V]

18-34

Analog

 Out

 X42/9

 [V]

18-35

Analog

 Out

 X42/11

 [V]

18-36

Analog

 Input

 X48/2

 [mA]

18-37

Temp.

 Input

 X48/4

18-38

Temp.

 Input

 X48/7

18-39

Temp.

 Input

 X48/10

18-5*

Ref.

 &

 Feedb.

18-50

Sensorless

 Readout

 [unit]

20-**

Drive

 Closed

 Loop

20-0*

Feedback

20-00

Feedback

 1

 Source

20-01

Feedback

 1

 Conversion

20-02

Feedback

 1

 Source

 Unit

20-03

Feedback

 2

 Source

20-04

Feedback

 2

 Conversion

20-05

Feedback

 2

 Source

 Unit

20-06

Feedback

 3

 Source

20-07

Feedback

 3

 Conversion

20-08

Feedback

 3

 Source

 Unit

20-12

Reference/Feedback

 Unit

20-13

Minimum

 Reference/Feedb.

20-14

Maximum

 Reference/Feedb.

20-2*

Feedback/Setpoint

20-20

Feedback

 Function

20-21

Setpoint

 1

20-22

Setpoint

 2

20-23

Setpoint

 3

20-3*

Feedb.

 Adv.

 Conv.

20-30

Refrigerant

20-31

User

 Defined

 Refrigerant

 A1

20-32

User

 Defined

 Refrigerant

 A2

20-33

User

 Defined

 Refrigerant

 A3

20-34

Duct

 1

 Area

 [m2]

20-35

Duct

 1

 Area

 [in2]

20-36

Duct

 2

 Area

 [m2]

20-37

Duct

 2

 Area

 [in2]

20-38

Air

 Density

 Factor

 [%]

20-6*

Sensorless

20-60

Sensorless

 Unit

20-69

Sensorless

 Information

20-7*

PID

 Autotuning

20-70

Closed

 Loop

 Type

20-71

PID

 Performance

20-72

PID

 Output

 Change

20-73

Minimum

 Feedback

 Level

20-74

Maximum

 Feedback

 Level

20-79

PID

 Autotuning

20-8*

PID

 Basic

 Settings

20-81

PID

 Normal/

 Inverse

 Control

20-82

PID

 Start

 Speed

 [RPM]

20-83

PID

 Start

 Speed

 [Hz]

20-84

On

 Reference

 Bandwidth

20-9*

PID

 Controller

20-91

PID

 Anti

 Windup

20-93

PID

 Proportional

 Gain

20-94

PID

 Integral

 Time

20-95

PID

 Differentiation

 Time

20-96

PID

 Diff.

 Gain

 Limit

21-**

Ext.

 Closed

 Loop

21-0*

Ext.

 CL

 Autotuning

21-00

Closed

 Loop

 Type

21-01

PID

 Performance

21-02

PID

 Output

 Change

21-03

Minimum

 Feedback

 Level

21-04

Maximum

 Feedback

 Level

21-09

PID

 Autotuning

21-1*

Ext.

 CL

 1

 Ref./Fb.

21-10

Ext.

 1

 Ref./Feedback

 Unit

21-11

Ext.

 1

 Minimum

 Reference

21-12

Ext.

 1

 Maximum

 Reference

21-13

Ext.

 1

 Reference

 Source

21-14

Ext.

 1

 Feedback

 Source

21-15

Ext.

 1

 Setpoint

21-17

Ext.

 1

 Reference

 [Unit]

21-18

Ext.

 1

 Feedback

 [Unit]

21-19

Ext.

 1

 Output

 [%]

21-2*

Ext.

 CL

 1

 PID

21-20

Ext.

 1

 Normal/Inverse

 Control

21-21

Ext.

 1

 Proportional

 Gain

21-22

Ext.

 1

 Integral

 Time

21-23

Ext.

 1

 Differentation

 Time

21-24

Ext.

 1

 Dif.

 Gain

 Limit

21-3*

Ext.

 CL

 2

 Ref./Fb.

21-30

Ext.

 2

 Ref./Feedback

 Unit

21-31

Ext.

 2

 Minimum

 Reference

21-32

Ext.

 2

 Maximum

 Reference

21-33

Ext.

 2

 Reference

 Source

21-34

Ext.

 2

 Feedback

 Source

21-35

Ext.

 2

 Setpoint

21-37

Ext.

 2

 Reference

 [Unit]

21-38

Ext.

 2

 Feedback

 [Unit]

21-39

Ext.

 2

 Output

 [%]

21-4*

Ext.

 CL

 2

 PID

21-40

Ext.

 2

 Normal/Inverse

 Control

21-41

Ext.

 2

 Proportional

 Gain

21-42

Ext.

 2

 Integral

 Time

21-43

Ext.

 2

 Differentation

 Time

21-44

Ext.

 2

 Dif.

 Gain

 Limit

21-5*

Ext.

 CL

 3

 Ref./Fb.

21-50

Ext.

 3

 Ref./Feedback

 Unit

21-51

Ext.

 3

 Minimum

 Reference

21-52

Ext.

 3

 Maximum

 Reference

21-53

Ext.

 3

 Reference

 Source

21-54

Ext.

 3

 Feedback

 Source

21-55

Ext.

 3

 Setpoint

21-57

Ext.

 3

 Reference

 [Unit]

21-58

Ext.

 3

 Feedback

 [Unit]

21-59

Ext.

 3

 Output

 [%]

21-6*

Ext.

 CL

 3

 PID

21-60

Ext.

 3

 Normal/Inverse

 Control

21-61

Ext.

 3

 Proportional

 Gain

21-62

Ext.

 3

 Integral

 Time

21-63

Ext.

 3

 Differentation

 Time

21-64

Ext.

 3

 Dif.

 Gain

 Limit

22-**

Appl.

 Functions

22-0*

Miscellaneous

22-00

External

 Interlock

 Delay

22-01

Power

 Filter

 Time

22-2*

No-Flow

 Detection

22-20

Low

 Power

 Auto

 Set-up

22-21

Low

 Power

 Detection

22-22

Low

 Speed

 Detection

22-23

No-Flow

 Function

22-24

No-Flow

 Delay

22-26

Dry

 Pump

 Function

22-27

Dry

 Pump

 Delay

22-3*

No-Flow

 Power

 Tuning

22-30

No-Flow

 Power

22-31

Power

 Correction

 Factor

22-32

Low

 Speed

 [RPM]

22-33

Low

 Speed

 [Hz]

22-34

Low

 Speed

 Power

 [kW]

22-35

Low

 Speed

 Power

 [HP]

22-36

High

 Speed

 [RPM]

22-37

High

 Speed

 [Hz]

22-38

High

 Speed

 Power

 [kW]

22-39

High

 Speed

 Power

 [HP]

22-4*

Sleep

 Mode

22-40

Minimum

 Run

 Time

22-41

Minimum

 Sleep

 Time

22-42

Wake-up

 Speed

 [RPM]

22-43

Wake-up

 Speed

 [Hz]

22-44

Wake-up

 Ref./FB

 Difference

22-45

Setpoint

 Boost

22-46

Maximum

 Boost

 Time

22-5*

End

 of

 Curve

22-50

End

 of

 Curve

 Function

22-51

End

 of

 Curve

 Delay

22-6*

Broken

 Belt

 Detection

22-60

Broken

 Belt

 Function

22-61

Broken

 Belt

 Torque

22-62

Broken

 Belt

 Delay

22-7*

Short

 Cycle

 Protection

22-75

Short

 Cycle

 Protection

22-76

Interval

 between

 Starts

22-77

Minimum

 Run

 Time

22-78

Minimum

 Run

 Time

 Override

22-79

Minimum

 Run

 Time

 Override

 Value

22-8*

Flow

 Compensation

22-80

Flow

 Compensation

22-81

Square-linear

 Curve

 Approximation

22-82

Work

 Point

 Calculation

22-83

Speed

 at

 No-Flow

 [RPM]

22-84

Speed

 at

 No-Flow

 [Hz]

22-85

Speed

 at

 Design

 Point

 [RPM]

22-86

Speed

 at

 Design

 Point

 [Hz]

22-87

Pressure

 at

 No-Flow

 Speed

22-88

Pressure

 at

 Rated

 Speed

22-89

Flow

 at

 Design

 Point

22-90

Flow

 at

 Rated

 Speed

23-**

Time-based

 Functions

23-0*

Timed

 Actions

23-00

ON

 Time

23-01

ON

 Action

23-02

OFF

 Time

23-03

OFF

 Action

23-04

Occurrence

23-0*

Timed

 Actions

 Settings

23-08

Timed

 Actions

 Mode

23-09

Timed

 Actions

 Reactivation

23-1*

Maintenance

23-10

Maintenance

 Item

23-11

Maintenance

 Action

23-12

Maintenance

 Time

 Base

23-13

Maintenance

 Time

 Interval

23-14

Maintenance

 Date

 and

 Time

23-1*

Maintenance

 Reset

23-15

Reset

 Maintenance

 Word

23-16

Maintenance

 Text

23-5*

Energy

 Log

23-50

Energy

 Log

 Resolution

23-51

Period

 Start

23-53

Energy

 Log

Programming

VLT

®

 HVAC Drive D-Frame

Operating Instructions

MG16D102 - VLT

®

 is a registered Danfoss trademark

33

5

5

Содержание VLT HVAC FC 100

Страница 1: ...MAKING MODERN LIVING POSSIBLE Operating Instructions D Frame VLT HVAC Drive FC 100...

Страница 2: ...r is connected to the AC mains the motor may be started by means of an external switch a serial bus command an input reference signal or a cleared fault condition Use appropriate cautions to guard aga...

Страница 3: ...Safety VLT HVAC Drive D Frame Operating Instructions MG16D102 VLT is a registered Danfoss trademark...

Страница 4: ...A 11 2 4 2 2 Earthing Grounding IP20 Enclosures 12 2 4 2 3 Earthing Grounding IP21 54 Enclosures 12 2 4 3 Motor Connection 12 2 4 4 Motor Cable 15 2 4 5 Motor Rotation Check 15 2 4 6 AC Mains Input Co...

Страница 5: ...29 5 4 International North American Default Parameter Settings 29 5 5 Parameter Menu Structure 30 5 5 1 Main Menu Structure 31 5 6 Remote Programming with MCT 10 Set up Software 35 6 Application Examp...

Страница 6: ...ons 58 10 2 General Technical Data 59 10 3 Fuse Tables 64 10 3 1 Protection 64 10 3 2 Non UL Compliance 64 10 3 3 UL Compliance 65 10 3 4 Connection Tightening Torques 65 Index 66 Contents VLT HVAC Dr...

Страница 7: ...y 2 04 05 06 2 RS 485 serial bus connector 10 Lifting ring 3 Digital I O and 24 V power supply 11 Mounting slot 4 Analog I O connector 12 Cable clamp PE 5 USB connector 13 Earth ground 6 Serial bus te...

Страница 8: ...waveform output The frequency and voltage of the output are regulated to control the motor speed or torque The frequency converter can vary the speed of the motor in response to system feedback such...

Страница 9: ...erters kW High Overload 75 90 110 132 160 200 250 315 315 kW Normal Overload 90 110 132 160 200 250 315 355 400 400 V D3h D3h D3h D4h D4h D4h 500 V D3h D3h D3h D4h D4h D4h 525 V D4h D3h D3h D4h D4h D4...

Страница 10: ...ad current for peak motor performance Motor size and frequency converter power must match for proper overload protection If frequency converter rating is less than motor full motor output cannot be ac...

Страница 11: ...Straps where Indicated WARNING The angle from the top of the frequency converter to the lifting cables should be 60 or greater 2 3 3 Wall Mounting IP21 NEMA 1 and IP54 NEMA 12 Units Consider the follo...

Страница 12: ...otor Analog Output Interface relay1 relay2 ON Terminated OFF Open Brake resistor NPN Sink PNP Source 240Vac 2A 400Vac 2A Illustration 2 2 WARNING EQUIPMENT HAZARD Rotating shafts and electrical equipm...

Страница 13: ...the quicker the trip response The overload provides Class 20 motor protection See 8 Warnings and Alarms for details on the trip function Because the motor wiring carries high frequency current it is i...

Страница 14: ...Use the clamps provided with the equipment for proper earth connections ground connections Do not earth ground one frequency converter to another in a daisy chain fashion Keep the earth ground wire c...

Страница 15: ...2 6 Earthing Grounding for IP21 54 Enclosures CAUTION GROUNDING HAZARD Do not use conduit connected to the frequency converter as a replacement for proper grounding Ground currents are higher than 3...

Страница 16: ...0 0 0 200 7 9 94 3 7 244 9 6 0 0 0 272 10 7 0 0 0 S U W R T V 3X M8x20 STUD WITH NUT SECTION A A MAINS TERMINALS MAINS TERMINAL SECTION B B MOTOR TERMINALS MOTOR TERMINAL 130BC305 10 Illustration 2 7...

Страница 17: ...INAL 130BC332 10 Illustration 2 9 Terminal Locations D2h A A B B 33 1 3 0 0 0 91 3 6 149 5 8 211 8 3 265 10 4 319 12 6 200 7 9 0 0 0 319 12 6 376 14 8 293 11 5 255 10 0 0 0 0 306 12 1 284 11 2 0 0 0 2...

Страница 18: ...rical codes for cable sizes Connect 3 phase AC input power wiring to terminals L1 L2 and L3 see Illustration 2 11 130BC254 10 2 1 Illustration 2 11 Connecting to AC Mains 1 Mains connection 2 Motor co...

Страница 19: ...centage value Screen type i e braided or twisted pattern a Aluminium clad with copper wire b Twisted copper wire or armoured steel wire cable c Single layer braided copper wire with varying percentage...

Страница 20: ...13 18 19 27 29 32 33 20 37 Illustration 2 17 Control Terminal Locations Connector 1 provides four programmable digital input terminals two additional digital terminals programmable as either input or...

Страница 21: ...nstalled Each node connected within a given network must have a unique node address across all segments Terminate each segment at both ends using either the termination switch S801 of the frequency co...

Страница 22: ...air flow for cooling EMC considerations Check for proper installation regarding electromagnetic compatibility Environmental consider ations See equipment label for the maximum ambient operating temper...

Страница 23: ...onal Programming Frequency converters require basic operational programming before running for best performance Basic operational programming requires entering motor nameplate data for the motor being...

Страница 24: ...tart It is the responsibility of the user to ensure safe operation under any condition Failure to ensure that the motor system and any attached equipment is ready for start could result in personal in...

Страница 25: ...s recommended after application set up by the user is completed CAUTION MOTOR START Ensure that the motor system and any attached equipment is ready for start It is the responsibility of the user to e...

Страница 26: ...ogramming Guide MG33MXYY for details on use of the NLCP 4 1 1 LCP Layout The LCP is divided into four functional groups see Illustration 4 1 Auto on Reset Hand on Off Status Quick Menu Main Menu Alarm...

Страница 27: ...Status Quick Menu Main Menu Alarm Log Illustration 4 4 Key Function Status Shows operational information In Auto mode press to toggle between status read out displays Press repeatedly to scroll throu...

Страница 28: ...nd at the bottom of the LCP 130BP046 10 Hand on Off Auto on Reset Illustration 4 6 Key Function Hand On Starts the frequency converter in local control Use the navigation keys to control frequency con...

Страница 29: ...f the frequency converter Initialisation can be through 14 22 Operation Mode or manually Initialisation using 14 22 Operation Mode does not change frequency converter data such as operating hours seri...

Страница 30: ...in open loop using the quick menu This procedure programs the frequency converter to receive a 0 10 V DC analog control signal on input terminal 53 The frequency converter will respond by providing 20...

Страница 31: ...er that the minimum voltage received on Terminal 53 0 V equals 20 Hz output 130BT773 11 Q3 21 14 7 0 00 A 1 1 Analog Reference 6 14 Terminal 53 Low Ref Feedb Value 000020 000 Illustration 5 8 10 6 15...

Страница 32: ...minal 18 Digital Input 8 Start 14 7 0 00A 1 1 Digital Inputs Illustration 5 13 5 4 International North American Default Parameter Settings Setting 0 03 Regional Settings 0 International or 1 North Ame...

Страница 33: ...requency converter with system details it needs to operate properly System details may include such things as input and output signal types programming terminals minimum and maximum signal ranges cust...

Страница 34: ...r Ramps 3 80 Jog Ramp Time 3 81 Quick Stop Ramp Time 3 82 Starting Ramp Up Time 3 9 Digital Pot Meter 3 90 Step Size 3 91 Ramp Time 3 92 Power Restore 3 93 Maximum Limit 3 94 Minimum Limit 3 95 Ramp D...

Страница 35: ...tance 12 21 Process Data Config Write 12 22 Process Data Config Read 12 27 Primary Master 12 28 Store Data Values 12 29 Store Always 12 3 EtherNet IP 12 30 Warning Parameter 12 31 Net Reference 12 32...

Страница 36: ...ID Start Speed Hz 20 84 On Reference Bandwidth 20 9 PID Controller 20 91 PID Anti Windup 20 93 PID Proportional Gain 20 94 PID Integral Time 20 95 PID Differentiation Time 20 96 PID Diff Gain Limit 21...

Страница 37: ...Feedb Value 26 25 Term X42 3 High Ref Feedb Value 26 26 Term X42 3 Filter Time Constant 26 27 Term X42 3 Live Zero 26 3 Analog Input X42 5 26 30 Terminal X42 5 Low Voltage 26 31 Terminal X42 5 High Vo...

Страница 38: ...oaded to the frequency converter Or the entire frequency converter profile can be loaded onto the PC for back up storage or analysis The USB connector or RS 485 terminal are available for connecting t...

Страница 39: ...nput 2 Coast inverse Default Value Notes comments Parameter group 1 2 must be set according to motor Table 6 1 AMA with T27 Connected Parameters FC 24 V 24 V D IN D IN D IN COM D IN D IN D IN D IN 10...

Страница 40: ...9 Terminal 37 Safe Stop 1 Safe Stop Alarm Default Value Notes comments If 5 12 Terminal 27 Digital Input is set to 0 No operation a jumper wire to terminal 27 is not needed Table 6 5 Start Stop Comman...

Страница 41: ...Notes comments Table 6 8 External Alarm Reset Parameters FC 24 V 24 V D IN D IN D IN COM D IN D IN D IN D IN 10 V A IN A IN COM A OUT COM 12 13 18 19 20 27 29 32 33 37 50 53 54 55 42 39 A53 U I 5k 13...

Страница 42: ...RS 485 Network Connection CAUTION Thermistors must use reinforced or double insulation to meet PELV insulation requirements Parameters FC 24 V 24 V D IN D IN D IN COM D IN D IN D IN D IN 10 V A IN A...

Страница 43: ...rnal equipment may then indicate that service may be required If the feedback error goes below the limit again within 5 s then the frequency converter continues and the warning disappears But Relay 1...

Страница 44: ...nals and or the serial communi cation Hand on The frequency converter can be controlled by the navigation keys on the LCP Stop commands reset reversing DC brake and other signals applied to the contro...

Страница 45: ...ed down Operation status Jog request A jog command has been given but the motor will be stopped until a run permissive signal is received via a digital input Jogging The motor is running as programmed...

Страница 46: ...d the motor will start after the start delay time expires Start fwd rev Start forward and start reverse were selected as functions for two different digital inputs parameter group 5 1 The motor will s...

Страница 47: ...frequency converter logic will continue to operate and monitor the frequency converter status After the fault condition is remedied the frequency converter can be reset It will then be ready to start...

Страница 48: ...ts Auto on Reset Hand on Off B a c k C a n c e l Info OK On Alarm Warn 130BB467 10 Illustration 8 3 Warn LED Alarm LED Warning ON OFF Alarm OFF ON Flashing Trip Lock ON ON Flashing Table 8 1 Warnings...

Страница 49: ...istor short circuited X 26 Brake resistor power limit X X 2 13 Brake Power Monitoring 27 Brake chopper short circuited X X 28 Brake check X X 2 15 Brake Check 29 Drive over temperature X X X 30 Motor...

Страница 50: ...73 Safe Stop Auto Restart 76 Power Unit Setup X 77 Reduced Power Mode 79 Illegal PS config X X 80 Drive Initialized to Default Value X 91 Analog input 54 wrong settings X 92 NoFlow X X 22 2 93 Dry Pum...

Страница 51: ...e intermediate circuit voltage DC is lower than the low voltage warning limit The limit is dependent on the frequency converter voltage rating The unit is still active WARNING ALARM 7 DC overvoltage I...

Страница 52: ...imit is exceeded during ramp up extend the ramp up time If the generator torque limit is exceeded during ramp down extend the ramp down time If torque limit occurs while running possibly increase the...

Страница 53: ...n 90 of the brake resistance power If 2 Trip is selected in 2 13 Brake Power Monitoring the frequency converter will trip when the dissipated braking power reaches 100 WARNING There is a risk of subst...

Страница 54: ...ocessor software version 1299 Option SW in slot A is too old No Text 1300 Option SW in slot B is too old 1301 Option SW in slot C0 is too old 1302 Option SW in slot C1 is too old 1315 Option SW in slo...

Страница 55: ...thin the specified range in 4 11 Motor Speed Low Limit RPM and 4 13 Motor Speed High Limit RPM the frequency converter shows a warning When the speed is below the specified limit in 1 86 Trip Speed Lo...

Страница 56: ...eration can be resumed when the applies 24 V DC to T 37 again when the motor temperature reaches an acceptable level and when the Digital Input from the is deactivated When that happens a reset signal...

Страница 57: ...verter for normal operation WARNING 251 New typecode The power card or other components have been replaced and the typecode changed Reset to remove the warning and resume normal operation Warnings and...

Страница 58: ...Check the wiring for shorts or incorrect connections If the display continues to cut out follow the procedure for display dark Motor not running Service switch open or missing motor connection Check...

Страница 59: ...amp time settings Check parameter group 2 0 DC brake and 3 0 Reference limits Open power fuses or circuit breaker trip Phase to phase short Motor or panel has a short phase to phase Check motor and pa...

Страница 60: ...parameters in parameter group 4 6 Check if noise and or vibration have been reduced to an acceptable limit Turn off over modulation in 14 03 Overmodulation Change switching pattern and frequency in p...

Страница 61: ...180 218 274 333 407 Continuous kVA at 460 V kVA 151 191 241 288 353 426 Max Input current Continuous at 400 V A 204 251 304 381 381 463 463 567 Continuous at 460 500 V A 183 231 291 348 348 427 427 51...

Страница 62: ...supply voltage True Power Factor 0 9 nominal at rated load Displacement Power Factor cos near unity 0 98 Switching on input supply L1 L2 L3 power ups maximum one time 2 minutes Environment according t...

Страница 63: ...oltage PELV and other high voltage terminals Mains Functional isolation PELV isolation Motor DC Bus High voltage Control 24V RS485 18 37 130BA117 10 Illustration 10 1 Pulse inputs Programmable pulse i...

Страница 64: ...ad DC 1 1 on 1 2 NO Resistive load 80 V DC 2 A Max terminal load DC 13 1 on 1 2 NO Inductive load 24 V DC 0 1 A Max terminal load AC 1 1 on 1 3 NC Resistive load 240 V AC 2 A Max terminal load AC 15 1...

Страница 65: ...rformance 10 C Temperature during storage transport 25 65 70 C Maximum altitude above sea level without derating 1000 m Maximum altitude above sea level with derating 3000 m Derating for high altitude...

Страница 66: ...If a mains phase is missing the frequency converter trips or issues a warning depending on the load Monitoring of the intermediate circuit voltage ensures that the frequency converter trips if the int...

Страница 67: ...Provide overload protection to avoid fire hazard due to overheating of the cables in the installation The frequency converter is equipped with an internal over current protection that can be used for...

Страница 68: ...0URD31KI0550 N250 170M4016 LA50QS600 4 L50S 600 FWH 600A 20 610 31 630 A50QS600 4 6 9URD31D08A0630 A070URD31KI0630 N315 170M4017 LA50QS800 4 L50S 800 FWH 800A 20 610 31 800 A50QS800 4 6 9URD32D08A0800...

Страница 69: ...gnal 27 28 41 System 5 Terminals 21 25 41 43 29 17 Wiring 9 10 11 19 Cooling Cooling 7 Clearance 19 Copying Parameter Settings 25 Current Limit 21 Rating 7 48 D DC Current 5 42 Link 48 Derating 62 63...

Страница 70: ...eeds 20 Status 5 Wiring 9 10 19 Mounting 19 Multiple Frequency Converters 10 12 N Navigation Keys 20 27 41 23 25 Noise Isolation 9 19 O Open Loop 27 62 Operation Keys 25 Optional Equipment 20 5 Output...

Страница 71: ...2 Supply Voltage 15 17 51 60 Surroundings 62 Switching Frequency 42 System Feedback 5 T Temperature Limits 19 Terminal 53 27 28 Programming 18 Programming Examples 29 Thermistor Thermistor 15 49 39 Co...

Страница 72: ...www danfoss com drives MG16D102 130R0290 MG16D102 Rev 2012 04 24...

Страница 73: ......

Отзывы: