Reinstall in reverse order of this procedure and tighten
hardware according to
NOTICE!
Note for reassembly: For the current sensor to face in
the proper direction, point the signal wire plug outward.
7.4.12 Mixing Fan
1.
Remove the power terminal mounting plate in
accordance with
.
2.
Remove the two screws (T25) to detach the fan
from the power terminal mounting plate.
Reinstall in reverse order of this procedure and tighten
hardware according to
7.4.13 Balance/High Frequency Card
7.4.13.1 400 V AC Power Size
1.
Remove the power terminal mounting plate in
accordance with
.
2.
Unplug the cable MK 100 on the balance/high
frequency card.
3.
Remove the one standoff (0.3 in [8 mm]) from the
corner of the card.
4.
Remove three nuts (0.3 in [8 mm]).
NOTICE!
Two of the nuts also hold in place the (+) DC and (-) DC
wire harness.
Reinstall in reverse order of this procedure and tighten
hardware according to
NOTICE!
Note the wire cable connections on the (+) UDC and (-)
UDC terminals.
2
3
4
5
6
7
8
130BX465.10
1
Figure 7.16 Balance/High Frequency Card and DC Capacitor
Bank
400 V unit shown, 690 V units are slightly different.
1
Balance/High frequency card 5
DC center capacitor
plate
2
Capacitor bank cover
6
(+) DC capacitor plate
3
(-) DC capacitor plate
7
Capacitor locking
panel
4
Mylar insulator
8
DC capacitor
Table 7.16 Legend to
7.4.13.2 690 V AC Power Size
1.
Remove the power terminal mounting plate in
accordance with
2.
Unplug the cable MK 100 on the balance/high
frequency card.
Disassembly and Assembly In...
Service Manual
MG94A222