6 Troubleshooting
Parameter 19-93 indicates the error status of the Center Winder Controller. Several different conditions can be detected.
NO ALARM
[0]
TENSION LIMIT DETECTED
[1]
FC ALARM
[2]
MCO305 ERROR
[3]
QSTOP
[4]
LOCAL MODE
[5]
Table 6.1:
Center winder error, par. 19-93
Turning the tension off resets all fault conditions while in remote mode.
All messages are shown in the LCP display of the FC 300 in short and in the APOSS software in plain text.
You can find brief information on the error messages in the table or detailed information in the following section.
The tables contain the messages in numerical order. Letters following a % sign represent variables which can be used in plain text at the corresponding
locations
Error no
Error Text
Description
103
Illegal axis num.
Axes not in system
105
Error not reset
Error not cleared
106
Home not done
Failed to move to HOME position
107
Home vel. zero
Home was executed with Home Velocity set to zero
108
Position error
Position error
109
Index not found
Index pulse (encoder) not found
110
Unknown cmm.
Unknow command
111
SW end limit
Software end limit activated
112
Unknown param.
Illegal parameter number
113
FC not enabled
FC 300 is not ready but the PID controller is active
114
Too many loops
Too many nested loops
115
Par. save failed
Parameter save failed
116
Param. memory
Parameters in memory are corrupted
117
Progr. memory
Programs in memory are corrupted
118
Reset by CPU
Reset by CPU
119
User abort
User abort
125
HW end limit
HQ end limit activated
149
Too many inter.
Too many interrupt functions
150
No ext. 24V
External supply is missing
151
Too many gosub
Too many nested GOSUB commands
152
Too many return
Too many RETURN commands
154
D. out overload
Digital Output overloaded
155
LINK failed
LINKGPAR command failed
162
Memory error
Error in veryfying; EEPROM: address % defect
170
Array size (DIM)
Error in DIM command
171
Array too small
Attempt was made to cross array bounds
179
Waitndx timeout
Timeout while waiting for index
184
Too many ontime
Too many time interrupts
187
Out of memory
No more room for variables
190
Memory locked
The program memory is write-protected
191
Illegal cam array
Curve array wrong
192
Encoder error
Encoder error
199
Internal MCO fault
Internal MCO fault
VLT
®
Center Winder MCO 352
6 Troubleshooting
MG.33.T1.02 - VLT
®
is a registered Danfoss trademark
33
6
Содержание VLT Center Winder MCO 352
Страница 10: ...4 How to Install VLT Center Winder MCO 352 10 MG 33 T1 02 VLT is a registered Danfoss trademark 4 ...
Страница 32: ...6 Troubleshooting VLT Center Winder MCO 352 32 MG 33 T1 02 VLT is a registered Danfoss trademark 6 ...
Страница 34: ...7 Appendix VLT Center Winder MCO 352 34 MG 33 T1 02 VLT is a registered Danfoss trademark 7 ...