Control Panel
(LCP)
Line 3 shows the parameter number and
name, while the status/value of the selected
parameter are shown in line 4.
■
Changing data
The procedure for changing data is the same in
Quick menu as Menu mode .
Pressing the [CHANGE DATA] key gives access
to changing the selected parameter, following
the flashing underlining in line 4.
■
Changing a text value
If the selected parameter is a text value, the text value
is changed by means of the [+/-] keys.
175ZA740.10
1500 rpm
SETUP
1
ENGLISH
SPEED
001 LANGUAGE
The bottom display line shows the text value that will be
entered (saved) when acknowledgement is given [OK].
■
Change of group of numeric data values
If the chosen parameter represents a numeric
data value, the chosen data value is changed
by means of the [+/-] keys.
175ZA741.10
1500 rpm
SETUP
1
0.37 KW
SPEED
102 MOTOR POWER
175ZA742.10
1500 rpm
SETUP
1
0.55 KW
SPEED
102 MOTOR POWER
The chosen data value is indicated by the digit flashing.
The bottom display line shows the data value that will
be entered (saved) when signing off with [OK].
■
Infinitely variable change of numeric data value
If the chosen parameter represents a numeric data
value, a digit is first selected by means of the [<>] keys.
175ZA743.10
1500 rpm
SETUP
1
SPEED
130 START SPEED
0
9
.0 rpm
Then the chosen digit is changed infinitely variably
by means of the [+/-] keys:
175ZA744.10
1500 rpm
SETUP
1
SPEED
130 START SPEED
1
0.0 rpm
The chosen digit is indicated by the digit flashing.
Line 4 shows the data value that will be entered
(saved) when signing off with [OK].
■
Changing of data value, step-by-step
Certain parameters can be changed step by step
or infinitely variably. This applies to Motor power
(parameter 102), Motor voltage (parameter 103)
and Motor frequency (parameter 104).
The parameters are changed both as a group of numeric
data values and as numeric data values infinitely variably.
■
Read out and programming of indexed parameters
Parameters are indexed when placed in a rolling stack.
Parameter 615 - 617 contain a historical log which
can be read out. Choose the actual parameter, press
the [CHANGE DATA] key and use the [+] and [-]
keys to scroll through the log of values. During the
read out line 4 of the display will flash.
If a bus option is mounted in the drive, the
programming of parameter 915 - 916 needs to be
carried through in the following way:
Choose the actual parameter, press the [CHANGE
DATA] key and use the [+] and [-] keys to scroll through
the different indexed values. To change the value of
the parameter, select the indexed value and press the
[CHANGE DATA] key. Using the [+] and [-] keys the
MG.55.A6.02 - VLT is a registered Danfoss trademark
49