VLT® 5000 Crane
Programming
PNU
Parameter
Range
Factory setting
Changes
Unit
Conversion
Data
Protection
#
2xx
description
References & Limits
during
operation
index
index
type
level
202
Output speed high
limit
0-5000 RPM
3000 RPM
Yes
11
67
6
1
205
Maximum reference
0.001-
100.000
3000
Yes
0
-3
4
1
207
Ramp-up time 1
0.05 - 3600
0.85 sec.
Yes
4
-2
7
1
208
Ramp-down time 1
0.05 - 3600
0.85 sec.
Yes
4
-2
7
1
211
Jog ramp time
0.05 - 3600
0.85 sec.
Yes
4
-2
7
1
212
Quick stop
ramp-down time
0.05 - 3600
0.85 sec.
Yes
4
-2
7
1
213
Jog speed
0 - 4500 RPM
200 RPM
Yes
11
67
6
2
221
Torque limit motor
mode
0.0% - 170%
160 %
Yes
24
-1
6
1
222
Torque limit
generator operation
0.0% - 170%
160 %
Yes
24
-1
6
1
234
Missing motor phase
Enable
Yes
0
0
5
1
235
Phase loss monitor
Enable
No
0
0
5
1
236
Low speed ref.
current
0 - 160%
50%
Yes
27
0
5
1
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
Conversion index/unit index:
This number refers to a conversion figure to
be used when writing or reading by means of
a frequency converter. Please refer to
Serial
Communication
in
Appendix
.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark