34
MG.30.A7.02 - VLT
®
is a registered Danfoss trademark
The following must be programmed:
Function
Parameter no.
Parameter value
Thermistor on terminal 16
400
Thermistor
Connection examples
Example 3:
START/STOP REVERSING, thermistor built-in motor connected to VLT
®
frequency converter.
Reference: 1 k
Ω
potentiometer, 0-10 V ~0-100% speed
NB:
Screen for control cables must be
connected as described in the chapter on
EMC-correct installation.
All settings are based on factory settings, but
motor data (parameters 103-105) must be set
according to the motor connected