4.3 France UTE Requirements
NOTE
In France, observe the UTE C 15-712-1 and NF C 15-100
requirements.
For installation in France, apply warning label to front of
inverter.
Illustration 4.1 Position of Warning Label
4.4 Installation
Parameter
Specification
Temperature
−
25 °C - +60 °C (>45 °C derating)
Environmental class
according to IEC
IEC60721-3-3
3K6/3B3/3S3/3M2
Air quality - general
ISA S71.04-1985
Level G2 (at 75% RH)
Air quality - coastal,
heavy industrial and
agricultural zones
Must be measured and classified acc. to
ISA S71.04-1985
Vibration
1G
Ingress protection
class
54
Max. operating
altitude
3000 m above sea level.
PELV protection is effective up to 2000
m above sea level only.
Installation
Avoid constant stream of water.
Avoid direct sunlight.
Ensure adequate air flow.
Mount on non-flammable surface.
Mount upright on vertical surface.
Prevent dust and ammonia gases.
Table 4.4 Conditions for Installation
Parameter
Condition
Specification
Wall Plate
Hole diameter
30 x 9 mm
Alignment
Perpendicular ± 5° all
angles
Table 4.5 Wall Plate Specifications