Standard FC spools
PVB is with LS
A/B
shuttle valve
Code number 157B....
PVB is without LS
A/B
shuttle valve
Press. compensated flow: l/min [US gal/min]
ISO symbol
Symbol
Press. compensated flow l/min [US gal/min]
F
130
[34.3]
E
100
[26.4]
D
65
[17.2]
C
40
[10.6]
B
25
[6.6]
A
10
[2.6]
AA
5 [1.3]
AA
5 [1.3]
A
10
[2.6]
B
25
[6.6]
C
40
[10.6]
D
65
[17.2]
E
100
[26.
4]
F
130
[34.3]
7026
7024
7023
7022
7021
7020
7025
B A
T
P
157-02.11
4-way, 3-position
Closed neutral position
7005
7000
7001
7002
7003
700
4
7006
7126
7124
7123
7122
7121
7120
7125
B A
T
P
157-03.11
4-way, 3-position
Throttled, open neutral position
7105
7100
7101
7102
7103
710
4
7106
-
-
-
-
-
-
-
3-way, 3-position
Closed neutral position, P
→
A
-
7200
7201
7202
7203
720
4
-
-
-
-
-
-
-
-
3-way, 3-position
Closed neutral position, P
→
B
-
-
7301
7302
7303
730
4
-
-
7424
7423
7422
7421
-
-
4-way, 3-position
Throttled, A
→
T in neutral position
-
-
7401
7402
7403
740
4
7406
Technical Information
PVG 32 Proportional Valve Group
Module selection chart
60 |
©
Danfoss | August 2017
520L0344 | BC00000038en-US0802
Содержание PVG 32
Страница 1: ...Technical Information Proportional Valve Group PVG 32 powersolutions danfoss com ...
Страница 73: ...Technical Information PVG 32 Proportional Valve Group Danfoss August 2017 520L0344 BC00000038en US0802 73 ...
Страница 74: ...Technical Information PVG 32 Proportional Valve Group 74 Danfoss August 2017 520L0344 BC00000038en US0802 ...
Страница 75: ...Technical Information PVG 32 Proportional Valve Group Danfoss August 2017 520L0344 BC00000038en US0802 75 ...