background image

Proportional Valve Group PVG 120

© Danfoss A/S, 2017-01  

 

AN00000354xx-04

 • Rev 0101 • Jan 2017 

PVE kontrol specifikationer

PVE control specifications

PVE Steuerungsspezifikationen

PVE spécifications de contrôle

PVE stik varianter

PVE connector variants

PVE Stecker varianten

PVE variantes de connecteur

PVE driftsbetingelser

PVE operating conditions

PVE Betriebsbedingungen

PVE conditions de 

fonctionnement

PVEO  Control Specification

Supply Voltage (U

DC

)

Rated

12 V

DC

24 V

DC

Range

11 

→ 

15 V

DC

22 

→ 

30 V

DC

Max. ripple

5 %

PVEH/PVES Control Specification

Supply Voltage (U

DC

)

Rated / Range

11 

→ 

32 V

DC

Max. ripple

5 %

Supply Voltage (U

S

)

Neutral

U

S

 = 0.5 • U

DC

Q: P 

 A

U

S

 = (0.5 

 0.25) • U

DC

Q: P 

 B

U

S

 = (0.5 

 0.75) • U

DC

Supply Voltage PWM (U

S

)

Neutral

U

S

 = 50% DUT

Q: P 

 A

U

S

 = 50% 

 25% DUT

Q: P 

 B

U

S

 = 50% 

 75% DUT

PWM Frequency (US)

Recommended

> 1000 Hz

Input Impedance

Rated

12 kΩ

Input Capacitance

Rated

100 nF

PVEO/PVEH/PVES Operating Conditions

Pilot Pressure

Nominal

13.5 bar [196 psi]

Minimum

10.0 bar [145 psi]

Maximum

15.0 bar [220 psi]

Storage Temp.

Ambient

-50°C 

 90°C [-58°F 

 194°F]

Operating Temp.

Ambient

-40°C 

 90°C [-40°F 

 194°F]

Oil Viscosity

Operating range

12 

 75 cSt [65 

 347 SUS]

Minimum

4 cSt [39 SUS]

Maximum

460 cSt [2128 SUS]

Oil Cleanliness

Maximum

18/16/13 (acc. to ISO 4406)

PVEH-U LED Characteristics

Color

LED view

Function

Green

Operating

Green @ 1.5 Hz

Neutral - Power Save

Red

Internal fault

Red @ 1.5 Hz

External or Float fault

Yellow

Disable Mode

PVEH/PVES LED Characteristics

Color

LED view

Function

Green

Operating

Green @ 1.5 Hz

Neutral - Power Save

Red

Internal fault

Red @ 1.5 Hz

External or Float fault

PVEO LED Characteristics

Color

LED view

Function

Green

Power ON

Содержание PVG 120

Страница 1: ...No F PVB A Port number week year and day manufacturing issue and series No G PVT week and year of manufacturing C PVG Nummer Woche und Jahr der Montage und Seriennummer D PVP Druckeinstellung E PVP Nummer Woche und Jahr der Herstellung und Seriennummer F PVB A Anschluss Nummer Woche und Jahr der Herstellung und Seriennummer G PVT Woche und Jahr der Herstellung C PVG numéro semaine et année de mont...

Страница 2: ...af stik Installation and plug orientation Montage und Ausrichtung des Steckers Montage et orientation de la prise PVB 1 2 3 4 5 6 7 8 L mm 168 235 302 369 436 503 570 637 L in 6 61 9 25 11 88 14 53 17 17 19 80 22 44 25 08 Plads til demontage Room for dismantling Platz für Demontage Espace pour démontage Tilslutning PVP pumpesidemodul Connection PVP pump side module Anschluss PVP pumpenseitiges Mod...

Страница 3: ...utting edge mit Dichtkante tranchant 35 N m 310 lbf in 40 N m 350 lbf in 60 N m 530 lbf in Tilspændingsmomenter Tightening torques Anzugsmomente Couples de serrage Nominel tryk Rated pressure Nomineller Druck Pression nominale Product Rated pressure PVG 120 400 bar 58 02 psi PVG 120 32 w PVS 300 bar 4351 psi PVG 120 32 w PVSI 350 bar 5076 psi PVG 120 w HIC steel 350 bar 5076 psi PVG 120 w HIC alum...

Страница 4: ...Max Anzugsmomente Couples de serrage maxi Port Port Anscshluss Orifice Størrelse Size Grösse Taille Gevind Threads Gewinde Filetage Tilspændingsmoment Tightening torque Anzugsmoment Couple de serrage P 1 in M12 18 dyb deep tief profondeur 18 68 N m 600 lbf in 7 16 14 UNC 0 7 dyb deep tief profondeur 0 7 68 N m 600 lbf in A B 3 4 in M10 17 dyb deep tief profondeur 17 45 N m 400 lbf in 3 8 16 UNC 0 ...

Страница 5: ... flow Einstellung des max Ölstroms Réglage de débit maxi Montering af håndtag Installation of lever Montage von Hebel Montage de manipulateur 22 5 52 5 82 5 1 1 2 5 1 4 2 5 17 2 5 19 5 19 5 V310014 A 8 1 N m 3 1 0 15N m 1 9 5 19 5 V310 018_B 10 0 39 6 1 N m 53 9 lbf in B A 3 0 12 V310101 B Q max Q max A Q max A Q max B Q max B Q max ...

Страница 6: ... PVE connector variants PVE Stecker varianten PVE variantes de connecteur Pin Pin 1 Pin 2 Pin 3 Pin 4 PVEO PVEO R 1x4 AMP UDC_A UDC_B GND GND 1x4 DEUTSCH UDC_A GND GND UDC_B 1x4 DIN UDC_A UDC_B GND PVEH PVES 1x4 AMP Us UDC GND Error 1x4 DEUTSCH Us Error GND UDC 1x4 DIN UDC Us Error GND 1x4 AMP 1x4 DEUTSCH 1x4 DIN 1 2 3 4 1 2 3 4 1 2 3 4 8 0 31 3 0 12 360 130 bar 360 1900 psi 35 Nm 310 lbf in 3 Nm ...

Страница 7: ...tral US 50 DUT Q P A US 50 25 DUT Q P B US 50 75 DUT PWM Frequency US Recommended 1000 Hz Input Impedance Rated 12 kΩ Input Capacitance Rated 100 nF PVEO PVEH PVES Operating Conditions Pilot Pressure Nominal 13 5 bar 196 psi Minimum 10 0 bar 145 psi Maximum 15 0 bar 220 psi Storage Temp Ambient 50 C 90 C 58 F 194 F Operating Temp Ambient 40 C 90 C 40 F 194 F Oil Viscosity Operating range 12 75 cSt...

Страница 8: ...parts of control system See also Technical information for PVE series 7 WWarnung Alle Fabrikate und Typen von Wegeventilen einschließlich Proportionalventile können versagen und schlimme Unfälle verursachen Es ist daher wichtig die Anwendung in allen Details zu analysieren Weil Proportionalventile unter vielen unterschiedlichen Arbeitsbedingungen und in vielen verschiedenen Anwendungen benutzt wer...