![Danfoss PVG 100 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/danfoss/pvg-100/pvg-100_technical-information_507212037.webp)
the return filter must be sized to suit the max. return oil flow. Pressure filters must be fitted to suit max.
pump oil flow.
Internal filters
The filters built into PVG 32 are not intended to filter the system but to protect important components
against large particles. Such particles can appear in the system as a result of pump damage, hose fracture,
use of quick-couplings, filter damage, starting up, contamination, etc. The filter in the electrical actuator
PVE protecting the solenoid valves has a mesh of 150 µm. Bursting pressure drop for internal filters is 25
bar [360 psi].
Technical Information
PVG 100 Proportional Valve Group
Other operating conditions
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502 | 37