When the pump is started and the main spools in the individual basic modules are in the neutral position,
oil flows from the pump, through connection P, across the pressure matching spool (11) to tank. The oil
flow led across the pressure matching spool determines the pump pressure (stand-by pressure).
When one or more of the main spools are actuated, the highest load pressure is fed through the shuttle
valve circuit (4, 7) to the spring chamber (10) behind the pressure matching spool, and completely or
partially closes the connection to tank. Pump pressure is applied to the opposite side of the pressure
matching spool. The pressure relief valve (1) will open should the load pressure exceed the set value,
diverting pump flow back to tank.
Optional PVPC with check valve option may be used in systems where it is necessary to operate the PVG
100 valve by means of the electrical remote control without pump flow.
For additional information about PVPC refer to the publication 520L0344.
Optional electrically actuated pilot shut off valve PVPP provides additional functional system safety by
removing pilot oil from the electrical actuation or hydraulic actuation system, disabling main spool
actuation. When the PVPP is used with the PVBZ P.O. check valve system it is possible to disable actuation
during mechanical actuation
Technical Information
PVG 100 Proportional Valve Group
Function
10 |
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502
Содержание PVG 100
Страница 1: ...Technical Information Proportional Valve Group PVG 100 www danfoss com ...
Страница 73: ...Technical Information PVG 100 Proportional Valve Group Danfoss May 2018 520L0720 BC00000039en US0502 73 ...
Страница 74: ...Technical Information PVG 100 Proportional Valve Group 74 Danfoss May 2018 520L0720 BC00000039en US0502 ...
Страница 75: ...Technical Information PVG 100 Proportional Valve Group Danfoss May 2018 520L0720 BC00000039en US0502 75 ...