![Danfoss PVG 100 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/danfoss/pvg-100/pvg-100_technical-information_507212016.webp)
Typical operating curve
0
0
Q max
Pressur
e
Fl
ow
P101 166E
PC setting
Simple closed-center circuit
P101 965
Once the closed center valve is opened, the PC control senses the immediate drop in system pressure
and increases pump flow by increasing the swashplate angle.
The pump continues to increase flow until system pressure reaches the PC setting. If system pressure
exceeds the PC setting, the PC control reduces the swashplate angle to maintain system pressure by
reducing flow.
The PC control continues to monitor system pressure and changes swashplate angle to match the output
flow with the work function pressure requirements.
If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum
displacement. In this condition, actual system pressure depends on the actuator load.
For additional system protection, install a relief valve in the pump outlet line. * Do not use the PVG 32
with bleed down load sense control.
Pressure compensated system characteristics
•
Constant pressure and variable flow
•
High pressure standby mode when flow is not needed
•
System flow adjusts to meet system requirements
•
Single pump can provide flow to multiple work functions
•
Quick response to system flow and pressure requirements
Typical applications for pressure compensated systems
•
Constant force cylinders (bailers, compactors, refuse trucks)
•
On/off fan drives
•
Drill rigs
•
Sweepers
•
Trenchers
Typical applications for remote pressure compensated systems:
•
Modulating fan drives
•
Anti-stall control with engine speed feedback
•
Front wheel assist
Technical Information
PVG 100 Proportional Valve Group
Function
16 |
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502
Содержание PVG 100
Страница 1: ...Technical Information Proportional Valve Group PVG 100 www danfoss com ...
Страница 73: ...Technical Information PVG 100 Proportional Valve Group Danfoss May 2018 520L0720 BC00000039en US0502 73 ...
Страница 74: ...Technical Information PVG 100 Proportional Valve Group 74 Danfoss May 2018 520L0720 BC00000039en US0502 ...
Страница 75: ...Technical Information PVG 100 Proportional Valve Group Danfoss May 2018 520L0720 BC00000039en US0502 75 ...