Example of a control system for manlift
Example of a control system for man-lift
Example of a control system for man-lift using PVE Fault monitoring input signals and signals from
external sensors to ensure the PLUS+1
®
main controllers correct function of the man-lift.
Typical PVE wiring block diagram
W
Warning
It is the responsibility of the equipment manufacturer that the control system incorporated in the
machine is declared as being in conformity with the relevant machine directives.
Technical Information
PVG 100 Proportional Valve Group
Safety
20 |
©
Danfoss | May 2018
520L0720 | BC00000039en-US0502