PVED-CLS AUX— soft-stop
AUX soft-stop can decrease flow to cylinders when wheels are close to end-stop to help prevent damage
and jerk. This parameter is used for mini steering wheel and open loop joystick devices.
Parameter
Conditions for value change
P3708-P3712
See
PVED-CLS soft-stop
on page 25 for configuration details.
Wheels may not return from end-stops or will do so slowly if flow is set too low.
Do not decrease P3708 below 200.
PVED-CLS AUX— anti-jerk
Anti-jerk can be used to decrease jerk in articulated vehicles. These parameters can be applied with a
mini steering wheel or open-loop joystick.
Parameter
Conditions for value change
P3698-P3718
See Section 11.6 Open Loop Anti-Jerk in the User Manual for configuration details.
PVED-CLS AUX— anti-drift
Anti-drift can be used to keep the mini steering wheel in the same position when driving straight ahead
by adding a percentage of full flow when the actual mini steering wheel angle does not match the ideal
angle.
Parameter
Conditions for value change
P3706, P3705
See Section 11.5 Open Loop Mini Wheel Anti-Drift in User Manual for details on setting parameters.
Application Guide
PVED-CLS startup guide
Parameter setting
28 |
©
Danfoss | October 2018