Fig. 2: Side B

Table 1: LED operation details

RED LED OFF

The device is not correctly powered.

RED LED blinking

The device is powered and the communication with the electronic thermostat is not 
established yet.

RED LED ON

The device is powered and the communication with the electronic thermostat is 
correctly established.

RED LED fast blinking

The device is powered while the communication with the electronic thermostat has 
been interrupted.

GREEN LED OFF

The modem is not running

GREEN LED fast blinking

The modem is not registered to the network

GREEN LED blinking

The modem is registered to the network

The PR-OCTO device gives the possibility to execute the lock command and to collect the diagnostic 
information only in conjunction with an electronic thermostat.

The current version of the PR-OCTO includes the compatibility with the thermostats listed in Table 2.

3. Compatibility

Table 2: Compatible electronic thermostats

Manufacturer

Models

Danfoss

ERC111, ERC112, EETa

Eliwell

EWPLUS400, EWPLUS961, EWPLUS974, EWPLUS974 Smart, EWPLUS978

Carel

PJP4C0HG00 (PYUG3R05R3, PYKM1Z051P), PZPU family (es. PZPUCOMB03K, PZPUCOMB06K), 

PYHB1R055S (PYFZ1Z056M), PZHBC0H00V, PYHB1R057F (PYHB1R05E9), PJP7C0HG00

Danf

oss

80G8252

P

C

O

COMM connector: 

the TTL communication port

with the electronic thermostat. This is also the
connector for the temperature probe inputs.

Power supply connector:

 100 – 240 V ~

Optional connector:

 the RS485/RS232

communication port for suitable thermostat.

Содержание PR-OCTO

Страница 1: ...User Guide Monitoring unit Type PR OCTO IoT Enabler for remote control and tracking of refrigeration equipment...

Страница 2: ...WiFi HotSpots to determine its position and transmit it to Alsense If in Alsense the refrigeration system is located in a position other than that transmitted by PR OCTO an alarm is notified on the m...

Страница 3: ...is registered to the network The PR OCTO device gives the possibility to execute the lock command and to collect the diagnostic information only in conjunction with an electronic thermostat The curre...

Страница 4: ...standard fast on connectors are included in the PR OCTO package Note If the power supply cable is not double insulated it must be physically separated from the COMM cable Concerning the COMM Cable the...

Страница 5: ...steps Step 1 Download the VBCTKSignalTester application from this URL http area riservata it vbctksignaltester 1 0 0 setup x86_32 exe Step 2 Install the VBCTKSignalTester application in a Windows PC...

Страница 6: ...connector side of the electronic thermostat hence a piece of plastic with an appropriate shape can be used If a piece of plastic is not available a metallic plate can be used but the covered area of...

Страница 7: ...detect and manage the door sensor itself For any clarification ask to your local Danfoss agent For the installation the following steps have to be performed Step 1 While the cooler is off put the OCTO...

Страница 8: ...to ship the equipment to the final customer Any shipment to the final customer must be notified with an e mail containing the equipment codes and the customer s warehouse address to support prosa dan...

Страница 9: ...R OCTO has to be embedded in the cooler and not accessible In case of installation on the back side of the cooler the PR OCTO has to be protected with an additional box to protect people from electric...

Страница 10: ...Danfoss Climate Solutions 2022 04 BC391624209008en 000201 10 ADAP KOOL...

Отзывы: