Once discovered the best position with respect to the Antenna Signal Level, it is possible to decide 

if it is the case to protect the Side B (the one with the connectors) of the OCTO. To this aim, it can be 

adopted the same approach that the cooler manufacturer uses to protect the connector side of the 

electronic thermostat, hence a piece of plastic with an appropriate shape can be used.

If a piece of plastic is not available, a metallic plate can be used but the covered area of the OCTO has 

to be as small as possible (the limit should be 5 cm from the front of the OCTO, as illustrated in Fig. 7).

a.

c.

e.

b.

d.

f.

Fig. 6: VBCTKSignalTester application screeeshots.

User Guide | Monitoring unit, type PR-OCTO

6 | BC391624209008en-000201

© Danfoss | Climate Solutions | 2022.04

Содержание PR-OCTO

Страница 1: ...User Guide Monitoring unit Type PR OCTO IoT Enabler for remote control and tracking of refrigeration equipment...

Страница 2: ...WiFi HotSpots to determine its position and transmit it to Alsense If in Alsense the refrigeration system is located in a position other than that transmitted by PR OCTO an alarm is notified on the m...

Страница 3: ...is registered to the network The PR OCTO device gives the possibility to execute the lock command and to collect the diagnostic information only in conjunction with an electronic thermostat The curre...

Страница 4: ...standard fast on connectors are included in the PR OCTO package Note If the power supply cable is not double insulated it must be physically separated from the COMM cable Concerning the COMM Cable the...

Страница 5: ...steps Step 1 Download the VBCTKSignalTester application from this URL http area riservata it vbctksignaltester 1 0 0 setup x86_32 exe Step 2 Install the VBCTKSignalTester application in a Windows PC...

Страница 6: ...connector side of the electronic thermostat hence a piece of plastic with an appropriate shape can be used If a piece of plastic is not available a metallic plate can be used but the covered area of...

Страница 7: ...detect and manage the door sensor itself For any clarification ask to your local Danfoss agent For the installation the following steps have to be performed Step 1 While the cooler is off put the OCTO...

Страница 8: ...to ship the equipment to the final customer Any shipment to the final customer must be notified with an e mail containing the equipment codes and the customer s warehouse address to support prosa dan...