![Danfoss PAH 2 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/danfoss/pah-2/pah-2_installation-operation-and-maintenance-manual_3788517075.webp)
Installation
Impurities
8.
Prior to installation, burrs and chips and
other impurities must be removed from
pipes and hoses, eg with a felt plug
Chips or other impurities in the system
may cause damage
Sealing
9.
Fittings in screwed components to be
sealed with O-rings or bonded seals
Using teflon tape or packing yarn in
joints may cause damage
Grease
10.
Correctly limited quantities of grease
prevent seizing
Too much grease may develop
biofilm causing operational failures
Water supply
13.
Fill system with water before starting
to ensure lubrication and cooling
Starting without water will cause
damage
Coupling
12.
Ensure always to have 3 mm distance
between coupling flanges
Insufficient distance and/or misalign-
ment between the coupling flanges
will damage the pump
= min. 3 mm
0 mm
Assembly of coupling
11.
The coupling must be easy and simple
to assemble (see product instruction)
Never use force when assembling the
coupling parts, as this will damage the
motor/pump
75
180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022
Содержание PAH 2
Страница 1: ...Operating guide PAH pumps PAH 2 12 5 Installation Operation and Maintenance Manual hpp danfoss com ...
Страница 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Страница 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Страница 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Страница 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 49: ...hpp danfoss com Parts list PAHC 2 6 3 pumps Parts list PAH pumps PAH 2 4 6 3 10 12 5 hpp danfoss com ...
Страница 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...