Instruction
Pump instruction PAH / PAHT 2-12.5
36 |
© Danfoss | DHS (im) | 2022.07
1180R9379 | AQ188686503004en-000801 | PAH 2-12.5
2.2 Open-system design
A
Inlet line:
Dimension the inlet line to obtain mini-
mum pressure loss (large flow, minimum
pipe length, minimum number of bends/
connections, and fittings with small
pressure losses) .
B
Inlet filter:
Install the inlet filter (1) in front of the PAHT
pump (2) . Please consult the Danfoss filter
data sheet for guidance on how to select
the right filter .
C
Monitoring pressure switch:
Install the monitoring pressure switch (3)
between the filter and the pump inlet . Set
the minimum inlet pressure according to
specifications described in item 4, technical
data . The monitoring pressure switch stops
the pump if inlet pressure is lower than the
set minimum pressure .
D
Monitoring temperature switch:
Install the monitoring temperature switch
(4) between the filter and the pump, on
either side of the monitoring pressure
switch . Set the temperature value accord-
ing to technical data, item 4 . The monitor-
ing temperature switch stops the pump if
inlet temperature is higher than the set
value .
E
Hoses:
Always use flexible hoses (5) to minimize
vibrations and noise .
F
Inlet pressure:
In order to eliminate the risk of cavitation
and other pump damage, pump inlet
pressure must be maintained according to
specifications described in item 4, technical
data .
G
Non-return valve (6):
Should be installed after the outlet to
prevent pump backspin, which may ruin
the pump .
H
Pressure relief valve:
As the Danfoss PAHT pump begins to
create pressure and flow immediately after
start-up regardless of any counter pressure,
a pressure relief valve (7) should be
installed to prevent system damage .
Note: If a non-return valve is mounted in the
inlet line, a low-pressure relief valve is also
required between the non-return valve (8) and
the pump to protect against high-pressure
peaks .
M
2
SYSTEM
1
4
5
5
6
7
3
PI
PI
8
Содержание PAH 2
Страница 1: ...Operating guide PAH pumps PAH 2 12 5 Installation Operation and Maintenance Manual hpp danfoss com ...
Страница 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Страница 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Страница 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Страница 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 49: ...hpp danfoss com Parts list PAHC 2 6 3 pumps Parts list PAH pumps PAH 2 4 6 3 10 12 5 hpp danfoss com ...
Страница 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...