Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps
6
180R9379 | AQ188686503004en-000801 | PAH 2-12.5 | 07.2022
2.1 General information
Dangers that can arise from not following the
instructions:
When the pump or pump system is managed by
untrained personnel, there is a danger of:
• Death or fatal injuries
• Costly damages and claims
Electrical
hazard
All electrical installation work must only be
carried out by authorized personnel in
accordance with EN60204-1 and/or local
regulations .
It is recommended to install a lockable circuit
breaker to avoid inadvertent starting and/or
electrical hazard . The lockable circuit breaker
must be used during installation, operation and
maintenance .
It is recommended to place a local safety switch
nearby the pump, enabling service personnel to
cut power for the electric motor .
Protect the motor and other electrical equip-
ment from overloads with suitable equipment .
In case the pump delivered is ATEX certified, the
additional ATEX instruction must also be read .
!
Protective
garments
must be worn
Always wear suitable safety clothing when
handling the pump .
When working near the pump system, safety
shoes, safety glasses, hearing protection and
safety helmet must always be worn .
Under certain operational conditions the surface
of the pump can be above 60°C / 140°F .
Under these conditions the pump must be
labelled with a “Danger Hot” sign .
When using an electric motor, the motor must
always be supplied with adequate cooling
ventilation .
When using an electric motor together with a
VFD (
V
ariable
F
requency
D
rive), the motor must
be designed for operation with VFD . VFD
operation may increase the temperature inside
the electric motor if the motor is not designed
for VFD operation . This can damage the motor
and cause unintended breakdown .
Before start-up, the settings for all protective
devices, such as sensors/switches and safety
valves must be verified and free flow from safety
valves must be ensured .
All pipe and hose connections must be stress-
free mounted, securely fastened to the pump
and well supported . Improper installation will or
could result in personal injury and/or damage to
the pump .
Use of this manual does not relieve operation
and maintenance personnel of the responsibil-
ity of applying good judgment when operating
and maintaining the pump and its compo-
nents .
2.2 Preferred system design
Danfoss recommends to build systems with a
high degree of safety . Danfoss preferred system
design and P&ID are found in appendix 1, Data
sheet, and appendix 2, Instruction .
2. Safety
1.3 Manufacturer and customer service
address:
Danfoss A/S
High Pressure Pumps
Nordborgvej 81,
DK-6430 Nordborg
Denmark
Telephone: +45 7488 2222
Fax:
+45 7445 3831
Email: highpressurepumps@danfoss .com
Web: hpp .danfoss .com
Your local Danfoss pump distributor can be
found on our homepage .
1.4 Country specific information
1.4.1 United Kingdom
UK importer:
Danfoss Ltd .
22 Wycombe End
HP9 1NB Beaconsfield
United Kingdom
Содержание PAH 2
Страница 1: ...Operating guide PAH pumps PAH 2 12 5 Installation Operation and Maintenance Manual hpp danfoss com ...
Страница 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Страница 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Страница 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Страница 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 49: ...hpp danfoss com Parts list PAHC 2 6 3 pumps Parts list PAH pumps PAH 2 4 6 3 10 12 5 hpp danfoss com ...
Страница 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...