Data sheet
PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps
28 |
180R9379 | AQ188686503004en-000801 | PAH 2-12 .5
© Danfoss | DCS (im) | 2022.07
7.4 Closed-system design
A
Inlet line:
Dimension the inlet line to obtain mini-
mum pressure loss (large flow, minimum
pipe length, minimum number of bends/
connections, fittings with small pressure
losses and restrictions) .
B
Inlet filter:
Install the filter (1) in front of the tank (2) .
Please consult the Danfoss filter data sheet
for guidance on how to select the right
filter .
C
Monitoring pressure switch:
Install the monitoring pressure switch (3) in
front of the filter (1) . Set the maximum inlet
pressure to 2 barg (29 .0 psig) . The monitor-
ing pressure switch will stop the pump (5) if
inlet pressure is higher than 2 barg (29 .0
psig), indicating that the filter element
must be changed .
D
Monitoring temperature switch:
Install the monitoring temperature switch
(4) in the tank . Set the temperature value
according to technical data, item 4 . The
monitoring temperature stops the pump if
inlet temperature is higher than the set
value .
E
Hoses:
Always use flexible hoses (6) to minimize
vibrations and noise .
F
Inlet pressure:
In order to eliminate the risk of cavitation
and other pump damage, pump inlet
pressure must be maintained according to
specifications described in item 4, technical
data .
G
Non-return valve (7):
Should be installed after the outlet to
prevent pump backspin, which may ruin
the pump .
H
Pressure relief valve:
As the Danfoss PAH pump begins to create
pressure and flow immediately after
start-up regardless of any counter pressure,
a pressure relief valve (8) should be
installed to prevent system damage .
I
System water filling:
To ensure proper filtration of new water
(10) supplied to the system, always use the
filling valve (9) .
J
Minimum level switch:
Install the minimum level switch (11) above
the outlet of the reservoir . The level switch
must stop the pump if the water in the
reservoir is below the switch, which
indicates that the reservoir is empty .
Reservoir
PI
System
PI
M
PI
System
PI
M
1
2
3
4
5
5
7
6
1
2
3
4
6
6
7
8
5
9
10
11
Содержание PAH 2
Страница 1: ...Operating guide PAH pumps PAH 2 12 5 Installation Operation and Maintenance Manual hpp danfoss com ...
Страница 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Страница 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Страница 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Страница 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 49: ...hpp danfoss com Parts list PAHC 2 6 3 pumps Parts list PAH pumps PAH 2 4 6 3 10 12 5 hpp danfoss com ...
Страница 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Страница 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...